4  Basic Information (General) 

4.1  Proper use 

The display unit acquired by you is used in combination with a weighing plate and 
serves to determine the weighing value of material to be weighed. It is intended to be 
used as a “non-automatic weighing system”, i.e. the material to be weighed is 
manually and carefully placed in the centre of the weighing plate. As soon as a stable 
weighing value is reached the weighing value can be read. 
 

4.2  Improper Use 

Do not use display unit for dynamic weighing. In the event that small quantities are 
removed or added to the material to be weighed, incorrect weighing results can be 
displayed due to the “stability compensation“ in the display unit. (Example: Slowly 
draining fluids from a container on the balance.)  
Do not leave permanent load on the weighing pan. This may damage the measuring 
system. 
Impacts and overloading exceeding the stated maximum load (max) of the weighing 
plate, minus a possibly existing tare load, must be strictly avoided. Both, the weighing 
plate and the display unit may be damaged during this process. 
Never operate display unit in explosive environment. The serial version is not 
explosion protected. 
Changes to the display unit's design are not permitted. This may lead to incorrect 
weighing results, safety-related faults and destruction of the display unit. 
The display unit may only be operated in accordance with the described default 
settings. Other areas of use must be released by KERN in writing. 
 

 

Содержание VHP-T

Страница 1: ...9 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating and Installation Instructions Display units KERN VHP T Version 1 1 05 2016 GB VHP T BA_IA e 1611 Import r Impex Produkter AS...

Страница 2: ...5 2 Personnel training 8 6 Transport and storage 9 6 1 Testing upon acceptance 9 6 2 Packaging return transport 9 7 Unpacking and placing 10 7 1 Installation Site Location of Use 10 7 2 Unpacking 11...

Страница 3: ...1 3 9 Menu 19 10 Servicing maintenance disposal 20 10 1 Cleaning 20 10 2 Servicing maintenance 20 10 3 Disposal 20 10 4 Error messages 20 11 Instant help 21 12 Configure display unit 22 13 Declaration...

Страница 4: ...weighing cells Max 6 items 700 sensibility 1 0 2mv V Range calibration We recommend 50 max Data output RS232 Electric Supply Input voltage 100 V 240 V Installed rechargeable battery DC 6V 10Ah Housin...

Страница 5: ...VHP T BA_IA e 1611 5 2 Device overview VHP T 1 Printer 2 Display 3 Keyboard 4 Connections platforms load connection of battery 5 Case 1 2 3 4 5...

Страница 6: ...witch on Switch off Taring Display sum total Store weighing value Delete weighing values Printing Return key Setting the date Setting the time Entry of license plate Switch on and off background illum...

Страница 7: ...ial to be weighed incorrect weighing results can be displayed due to the stability compensation in the display unit Example Slowly draining fluids from a container on the balance Do not leave permanen...

Страница 8: ...user must define a suitable interval as well as type and scope of this test Information is available on KERN s home page www kern sohn com with regard to the monitoring of display units test substanc...

Страница 9: ...ible damage 6 2 Packaging return transport Keep all parts of the original packaging for a possibly required return Only use original packaging for returning Prior to dispatch disconnect all cables and...

Страница 10: ...st direct draft from open windows or doors Avoid jarring during weighing Protect the display unit and the weighing plate against high humidity vapours and dust Do not expose the display unit to extrem...

Страница 11: ...nit in a way that facilitates operation and where it is easy to see 7 5 Storage battery operation optional Before the first use the battery should be charged by connecting it to the mains power supply...

Страница 12: ...with the underlying physical weighing principle to the existing acceleration due to gravity at its place of location only if the weighing system has not already been adjusted to the location in the f...

Страница 13: ...Use button to change into the window for date input 3 Now enter the following password 878586 the last two ciphers can be ignored 4 Use the C button to change between the individual parameters 5 Sele...

Страница 14: ...ng display appears after acknowledgement of parameter 5 Calibration To select the platforms press the C button Use the button to select the respective platform Carry out zero point adjustment CAL ZERO...

Страница 15: ...required the device may be reset to zero at any time To unload the weighing system Press the zero display appears 8 4 Simple weighing Place drive on weighing goods at walking speed Read weighing resu...

Страница 16: ...net weight will be indicated The weight of the weighing container will be displayed as a minus number after removing the weighing container The tare procedure can be repeated as many times as necessa...

Страница 17: ...ed up to a total result axle and printed out See printout example below Axle load report 30 11 2014 16 03 34 SN 2 HGV license plate BLM Article 01 Wheel 1 70 kg Wheel 2 40 kg Axle 1 110 kg G 110 kg T...

Страница 18: ...o the window for date input 3 Now enter the following password 878586 the last two ciphers can be ignored 4 Use the C button to change between the individual parameters 5 Select the parameter 9 Select...

Страница 19: ...n the individual parameters 5 Using button select the corresponding parameter Menu overview Menu Function 1 Capacity Setting weighing scale capacity 2 Readability Setting weighing scale readability 3...

Страница 20: ...wer supply 10 3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used 10 4 Error messages...

Страница 21: ...eries inserted The displayed weight is permanently changing Draught air movement Table floor vibrations Weighing pan has contact with other objects Electromagnetic fields static charging choose differ...

Страница 22: ...ge between the individual parameters 5 Select the parameter 1 capacity 6 Confirm by pressing the button Enter capacity with the numeric keypad and subsequently confirm with button 7 Use the button to...

Страница 23: ...12 Use the button to return to the parameter list 13 Select the parameter 8 Mode Enter the corresponding platform quantity via the numeric keyboard up to 6 platforms available 14 Use the button to re...