PES-A02-IA-defsi-0610
15
4 Operation
1. Connect mains adapter and start the balance by pressing the ON/OFF key
2. Entering limiting values
3. Evaluation of readings via relay contacts
4. Status balance/contact
Status balance
Display
Contact
Reading outside condition No reading display
inactive
Reading outside range
No reading display
inactive
Input of invalid values
Five symbols appear
on the left
inactive
Error message
(o-ERR/u-ERR)
o-ERR/u-ERR
•
OFF during measure-
ment of limits 1-5
•
ON during ERR
During input
Input appears on display inactive
Waiting for stability
message as per tares
[M] flashing
Last display fixated
Stand-by
Stand by LED glowing
inactive
Sleep mode
Sleep LED glowing
Output of evaluation result
Automatic check of
balance at starting
[
88888888
] glowing
inactive
5. Output by external signal
•
Contacts and audio signals are started by the weighing result, but may also be
triggered by an external signal
•
Whilst the menu is set [
2B.
R.Q.m.
2
] there is an output of the weighing result for
approx. 200 ms after the signal was applied
•
For pulsed, external signals the output signal will follow after 100 ms at the
earliest