5.7  Lighting control 

(OSE 413, OSE 414, OSE 416, OSE 417) 

 
 
 
OSE 413, OSE 414 (reflected light) 

 

To operate the reflected light, there is a main switch on the right, rear corner of the 
stand base surface which you can use to switch the lighting on and off. 
 
The light intensity cannot be adjusted. 
 
 
 
 
 
OSE 416, OSE 417 (reflected and transmitted light) 

 

To operate the reflected and transmitted light, there is a main switch on the right, rear 
corner of the stand base surface. 
 
This switch has three positions: 
 

O position 

Lighting is switched off 

I position 

Transmitted light is switched on 

II position 

Reflected light is switched on 

 
 
Reflected light and transmitted light cannot be used at the same time. 
 
The light intensity cannot be adjusted. 
 
 
 

 

Содержание OSE 410

Страница 1: ...elei 1 D 72336 Balingen E mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com User instructions Stereo microscope KERN OSE 4 OSE 410 OSE 411 OSE 413 OSE 414...

Страница 2: ......

Страница 3: ...ssembly 8 5 Operation and functionality 10 5 1 Getting started 10 5 2 Adjusting the interpupillary distance 10 5 3 Adjusting the magnification 10 5 4 Dioptre adjustment and focussing 11 5 5 Adjusting...

Страница 4: ...cal parts in the base of the device must not be tampered with as in this area there is an additional risk of triggering an electric shock 1 2 Notes on the electrical system OSE 413 OSE 414 OSE 416 OSE...

Страница 5: ...older must not be rotated back too far If you do this there is a risk that the microscope could tip over When the microscope is not being used you should fit the objective cap and cover the microscope...

Страница 6: ...these are highly flammable substances You must therefore keep it away from naked flames and electrical devices which can be switched on and off and only use it in well ventilated rooms However organi...

Страница 7: ...OSE 4 BA e 1510 6 2 Nomenclature Using the OSE 416 as an example with reflected and transmitted light illumination...

Страница 8: ...Objective Stand Illumination OSE 410 Binocular WF 10x 20 mm 20 1x 3x Pillar OSE 411 Binocular WF 10x 20 mm 20 2x 4x Pillar OSE 413 Binocular WF 10x 20 mm 20 1x 3x Pillar 0 21W LED reflected light OSE...

Страница 9: ...e the protective film which covers them When doing this make sure that you do not touch the optical lenses with your fingers In general you should avoid using two eyepieces with different magnificatio...

Страница 10: ...9 OSE 4 BA e 1510 Assembled stereo microscope...

Страница 11: ...So each time a different person uses the microscope the gap between the two eyepieces must be re adjusted While you are looking through the eyepieces use one hand to hold the righthand or lefthand pri...

Страница 12: ...through the righthand eyepiece without dioptre adjustment ring with the right eye and bring the object into focus by using the focus control dials 4 Now set the largest magnification 5 Once again stil...

Страница 13: ...eased On one hand this function can help to make it easier to adjust the focus and on the other hand it can prevent the microscope head from slipping down unintentionally In this way you can avoid pos...

Страница 14: ...ed by the glasses symbol on the side They are also marked in the item description by an additional H example HSWF 10x 23 mm When fitting the eye cups make sure that the dioptre setting is not moved We...

Страница 15: ...ight intensity cannot be adjusted OSE 416 OSE 417 reflected and transmitted light To operate the reflected and transmitted light there is a main switch on the right rear corner of the stand base surfa...

Страница 16: ...quirements a goose neck lighting unit is placed next to in front of or behind the microscope The light source is in the housing of the unit and is emitted through one or several optical fibre cables T...

Страница 17: ...tand Pillar without lighting Pillar with 0 21W LED lighting reflected light Pillar with 0 21W LED lighting Transmitted light and reflected light Stand inlay black white 59 5 mm OZB A4816 Frosted glass...

Страница 18: ...ufficient The wrong bulb has been used The input voltage is too low Optical unit Problem Possible causes You can see two images The interpupillary distance is not set correctly The magnifications of t...

Страница 19: ...materials which you can dispose of at your local recycling centre Disposal of the storage box and device must be carried out by the operator in accordance with all national or regional laws in force...

Отзывы: