Warranty 

Warranty claims shall be voided in case  

 

ƒ

  Our conditions in the operation manual are ignored 

ƒ

  The appliance is used outside the described uses 

ƒ

  The appliance is modified or opened 

ƒ

  Mechanical damage and damage caused by media, liquids 

ƒ

  Natural wear and tear 

ƒ

  The appliance is improperly set up or incorrectly electrically 

connected 

ƒ

  The measuring system is overloaded 

ƒ

  Dropping the balance 

 

Test device 

control 

In the framework of quality assurance the measuring-related 
properties of the balance and, if applicable, the testing weight, 
must be checked regularly. The responsible user must define a 
suitable interval as well as type and scope of this test. 
Information is available on KERN’s home page (www.kern-
sohn.com) with regard to the monitoring of balance test 
substances and the test weights required for this. In KERN’s 
accredited DKD calibration laboratory test weights and 
balances may be calibrated (return to the national standard) 
fast and at moderate cost. 

 

 

 

Содержание MPU 250K100

Страница 1: ...H Ziegelei 1 D 72336 Balingen email info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating instructions Personal scales KERN MPU Version 1 1 01 2010 GB M...

Страница 2: ...recautions 7 5 Transportation Storage 7 6 Unpacking Setup and Commissioning 8 6 1 Installation 10 7 Operation 12 8 Adjustment 15 9 BMI trend display 20 10 Data output 21 11 Printer mode 22 11 1 Printo...

Страница 3: ...Adjustment weight 200 kg Height measurement cm 80 220 Height measurement tolerance 1 cm Supply voltage 220V 240 V AC 50 Hz Electric Supply Secondary voltage powerpack 12 V 500 mA Operating temperature...

Страница 4: ...nce overview For assembly see Section 7 1 2 3 1 6 4 7 7 5 5 7 7 1 Ultrasonic sensor 2 Display 3 Keyboard only for servicing purposes 4 Connections 5 Rollers 6 Weighing plate 7 Adjustable feet MPU BA e...

Страница 5: ...isplayed due to the stability compensation in the balance Example Slowly draining fluids from a container on the balance Do not leave permanent load on the weighing plate This may damage the measuring...

Страница 6: ...pping the balance Test device control In the framework of quality assurance the measuring related properties of the balance and if applicable the testing weight must be checked regularly The responsib...

Страница 7: ...ving the appliance please check packaging immediately and the appliance itself when unpacking for possible visible damage Packing Return transport Keep all parts of the original packaging for a possib...

Страница 8: ...doors Avoid jarring during weighing Protect the balance against high humidity vapors and dust Do not expose the device to extreme dampness for longer periods of time Non permitted condensation condens...

Страница 9: ...rately from the bottom unit see Fig 1 Screws Interface cable Operating instructions Fig 1 1 Top unit 2 Bottom unit Placing The assembled scales are 2 40 m high Maintain a gap of 30 cm on all sides awa...

Страница 10: ...ure without fail that the existing cable connection to the keyboard is not disconnected Insert the top unit into the bottom unit Insert the strut into the guide in the aluminium frame for this purpose...

Страница 11: ...AD CELL measuring cell CAUTION Ensure correct allocation of plug connectors as there is risk of confusion Close the display cover and tighten the 6 screws on the back Fig 2 This fixes the cover in pla...

Страница 12: ...vicing purposes Overview of displays 1 Weight value 2 Height data 3 BMI value temperature 4 BMI ranges see Chapter 9 5 BMI value in the underweight range 6 BMI value in the normal weight range 7 BMI v...

Страница 13: ...working properly 24 Q STEP UP Example If Step up is displayed the scales are now ready for operation Weighing Stand upright in the centre of the scales without shoes Do not move during the measuring p...

Страница 14: ...BMI See Chapter 9 will be displayed The LED displays the corresponding BMI trend The above results remain frozen for approx 5 seconds after stepping off the scales Further measurement can only be car...

Страница 15: ...This adjustment process must be carried out for the first commissioning after each change of location as well as in case of fluctuating environment temperature To receive accurate measuring values it...

Страница 16: ...yed as last appears Furthermore LOAd is displayed Change adjustment weight Example 30 0 kg Press and keep pressed Display goes to 0 0 The adjustment weight is deleted Press and keep pressed Enter the...

Страница 17: ...With double click on shift decimal point to the left 3 0 With an other double click on shift decimal point to the left 30 0 Press CLEAr appears 17 MPU BA e 0911...

Страница 18: ...appears the entered adjustment weight 30 0 and PUt Place the adjustment weight in the center of the weighing surface The set adjustment weight must also be placed upon Press CALib and LOAd appear More...

Страница 19: ...24 Q STEP UP Save with SAVED appears The adjustment is herewith concluded The balance changes automatically into weighing mode HIGH ON and StEP UP is displayed 19 MPU BA e 0911...

Страница 20: ...en 27 5 and 25 0 between 25 0 and 22 8 between 22 8 and 20 6 between 20 6 and 18 5 between 18 5 and 17 5 between 17 5 and 16 5 below or equal to 16 5 These figures are only guide values There may be s...

Страница 21: ...typically equipped with a RS 232C interface Connections 1 Serial interface 2 Serial interface 3 Not available 4 Connection for plug in power pack 4 3 2 1 Interface parameters Baud rate 9600 Data Bit 8...

Страница 22: ...included in the scope of supply Communication parameters Baud rate bits and parity need to be set on the connected devices as specified in Chapter 10 Interface parameters 11 1 Printout example Standa...

Страница 23: ...d oFF Set on Press data and User on or off will appear Use to change between on and oFF Set oFF Acknowledge by SAVE is displayed Confirm anew by pressing done is shortly displayed followed by High on...

Страница 24: ...ion is adjusted The weighing values are printed out automatically 11 3 Setting manual data output Carry out the following adjustments as in 11 2 Data Auto off Data User on By pressing the key the weig...

Страница 25: ...25 MPU BA e 0911 12 Error messages no LC An incorrect power pack has been connected HIGH OFF Height measurement and BMI measurement do not work The temperature display goes to 99...

Страница 26: ...t fluid from penetrating into device Finish by polishing with dry soft cloth Remove dirt immediately Service maintenance The appliance may only be opened by trained service technicians who are authori...

Страница 27: ...s or is not correctly positioned Electromagnetic fields static charging choose different location switch off interfering device if possible The display of the balance is not at zero Adjustment is no l...

Отзывы: