MPL-BA-e-1710
5
2 Declaration of conformity
The current EC/EU Conformity declaration can be found online in:
www.kern-sohn.com/ce
Страница 1: ...GmbH Ziegelei 1 D 72336 Balingen E Mail info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operation manual Personal scales KERN MPL Version 1 0 2017 09 GB MPL...
Страница 2: ...cautions 9 5 1 Pay attention to the instructions in the Operation Manual 9 6 Transport and storage 9 6 1 Testing upon acceptance 9 6 2 Packaging 9 7 Unpacking Setup and Commissioning 10 7 1 Installati...
Страница 3: ...1 kg Weighing Units kg lb Recommended adjustment weight not added class 250 kg M1 Stabilization time 2 sec Operating temperature 10 C 40 C Humidity of air max 80 not condensing Battery 4 x 1 5 V AA Op...
Страница 4: ...4 MPL BA e 1710 1 1 Dimensions...
Страница 5: ...MPL BA e 1710 5 2 Declaration of conformity The current EC EU Conformity declaration can be found online in www kern sohn com ce...
Страница 6: ...6 MPL BA e 1710 3 Appliance overview 1 Display 2 Buttons 3 Weighing pan Bottom of the balance 4 Adjustment button 5 Weighing unit switching kg lb...
Страница 7: ...e 1710 7 3 1 Keyboard overview Call up BMI function Confirm entry in menu Taring Scroll forward in menu 3 2 Overview of display kg Kilogram HOLD Hold function Battery symbol BMI Body Mass Index cm Cen...
Страница 8: ...max under all circumstances This could cause damage to the balance Never operate balance in explosive environment The serial version is not explosion protected The structure of the balance may not be...
Страница 9: ...s operation manual before setup and commissioning even if you are already familiar with KERN balances 6 Transport and storage 6 1 Testing upon acceptance When receiving the appliance please check pack...
Страница 10: ...the balance against direct draughts due to open windows and doors Avoid jarring during weighing Protect the balance against high humidity vapours and dust Do not expose the device to extreme dampness...
Страница 11: ...it using the two screws 2 see fig 7 3 Battery operation The battery compartment is located at the rear side of the display unit Open the battery compartment and insert the four batteries according to...
Страница 12: ...ature To receive accurate measuring values it is also recommended to adjust the display unit periodically in weighing operation Keep adjustment weight ready Incline the balance to a side Press the adj...
Страница 13: ...tions are considered normal 9 1 Weighing The weighing scale offers two operating modes Weighing with Step on stepping on the weighing plate Weighing with Tap on tapping on the weighing plate Weighing...
Страница 14: ...n for a short time Afterwards the scales will turn off automatically example To leave either step again on the weighing plate or press any key or wait for Auto Off 9 2 Taring When the weight of the ob...
Страница 15: ...The value of the body height increases Press until the respective body height is displayed then release example Press The calculated BMI value of the person will be displayed example Classification of...
Страница 16: ...ust be carried out by operator according to valid national or regional law of the location where the appliance is used 11 Error messages Err on the display indicates that the weighing range has been e...