background image

 

 

 

 

 

 

MPE_HNM / MPE_PNM -SH-e-1810

 

 

 

 
 

GB

 

KERN MPE_HNM / MPE_PNM 

Version 1.0  07/2018 

Servicemanual

 

 

 

 

Contents 

 

1

 

Basic Information........................................................................................... 3

 

2

 

Appliance overview ....................................................................................... 4

 

3

 

Keyboard overview ........................................................................................ 6

 

4

 

Overview of display ....................................................................................... 7

 

4.1

 

Balance assembly and installation ............................................................................................. 7

 

4.2

 

Mains connection ........................................................................................................................ 7

 

4.3

 

Battery operation is possible by obtaining an optional battery power pack. .............................. 8

 

4.4

 

Battery operation ........................................................................................................................ 9

 

4.5

 

Insert batteries ............................................................................................................................ 9

 

5

 

The menu ...................................................................................................... 10

 

5.1

 

Navigation in the menu ............................................................................................................. 10

 

5.2

 

Menu overview ......................................................................................................................... 11

 

6

 

Data output RS 232 ...................................................................................... 14

 

6.1

 

Pin allocation of balance output bushing: ................................................................................. 14

 

6.2

 

Technical data .......................................................................................................................... 14

 

6.3

 

Position adjustment switch and seals: ...................................................................................... 15

 

6.4

 

Verification validity period (current status in G) ........................................................................ 15

 

7

 

Adjustment ................................................................................................... 16

 

7.1

 

Procedure: ................................................................................................................................ 17

 

8

 

MAINTENANCE ............................................................................................ 19

 

8.1

 

General ..................................................................................................................................... 19

 

8.2

 

Error Codes .............................................................................................................................. 19

 

8.3

 

Determine the Problem............................................................................................................. 20

 

8.4

 

Check the Load cell .................................................................................................................. 21

 

8.5

 

Checking the different Voltages ............................................................................................... 21

 

8.6

 

Trouble Shooting ...................................................................................................................... 22

 

9

 

Replace Main Board ..................................................................................... 23

 

10

 

DRAWING ..................................................................................................... 24

 

10.1

 

MPE_HM .................................................................................................................................. 24

 

 
 

 

Содержание MPE 250K100HNM

Страница 1: ...fo kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Service Manual Personal floor scale with BMI function KERN MPE_HNM MPE_PNM Type MPE 250K100HNM Type MPE 250K100P...

Страница 2: ...ation 9 4 5 Insert batteries 9 5 The menu 10 5 1 Navigation in the menu 10 5 2 Menu overview 11 6 Data output RS 232 14 6 1 Pin allocation of balance output bushing 14 6 2 Technical data 14 6 3 Positi...

Страница 3: ...roval A violation of this specification will result in a loss of the type approval After successful repair the balance will have to be reverified before it can be used again in a statutorily regulated...

Страница 4: ...4 MPE_HNM MPE_PNM SH e 1810 2 Appliance overview 1 Height measuring stick MPE HM models only 2 Display Unit 3 Weighing platform anti slip surface 4 Rubber feet height adjustable Underside 5 Rolls...

Страница 5: ...MPE_HNM MPE_PNM SH e 1810 5 Secondary display at rear Display unit at rear 5 Rechargeable battery compartment 6 Mains connection 7 RS 232 C...

Страница 6: ...stable weight value BMI key Calculation of the Body Mass Index PRINT button Data transfer via interface In menu Confirm selection For numeric entry Confirm numerical value Function key In menu Call up...

Страница 7: ...ce assembly and installation Level balance with foot screws until the air bubble of the water balance is in the prescribed circle Check levelling regularly 4 2 Mains connection Power is supplied by th...

Страница 8: ...dicates that the battery is almost exhausted The weighing scale will remain ready for operation for a few more minutes before switching off in order to save battery s operating instructions correspond...

Страница 9: ...ies are empty in the balance display appears the symbol Change batteries To save battery power the balance switches off automatically see operating instructions corresponding to the device chap 11 6 A...

Страница 10: ...new verification wire seal mark fitted before it can be reused for applications subject to verification 5 1 Navigation in the menu Call up menu In weighing mode press and the first function F1 oFF wil...

Страница 11: ...confirm with P Prt Weight will be added to summation memory and printed after pressing PRINT P Cont Continuous data output Series Not documented ASK Remote control instructions W Send all weighing re...

Страница 12: ...2 Not documented Cont 3 Not documented 4 Printer type After the data output format has been confirmed the currently set printer type will be displayed Select the desired printer type by and confirm b...

Страница 13: ...osition see operating instructions corresponding to the device chap 17 Display speed 15 Not documented 30 60 7 5 Adjustment see operating instructions corresponding to the device chap 18 tri Not docum...

Страница 14: ...ter Faultless operation requires an adequate KERN interface cable Communication parameters baud rate bits and parity of balance and printer must match For detailed description of interface parameters...

Страница 15: ...for example doctor s offices and nursing homes unlimited Baby weighing scales and mechanical birth weight scales 4 year Bed scales 2 year Scales in dialysis stations unlimited Rehab clinics and healt...

Страница 16: ...e the required adjustment weight The adjustment weight to be applied depends on the capacity of a weighing scale see chap 1 Carry out adjustment as closely as possible to admissible maximum load of we...

Страница 17: ...chap 16 Press and dESC will appear Press repeatedly until CAL will be displayed To confirm press and UnloAd will appear Ensure that there are no objects on the weighing pan Wait until the stability d...

Страница 18: ...pears Confirm by pressing PASS will be displayed The balance carries out a selftest after that Err19 will be displayed and a signal will sound Switch off the balance Take away adjustment weight Turn o...

Страница 19: ...by using format yy mm dd Err 2 Incorrect time Enter the time by using format hh mm ss Err 4 Zero setting error Zero setting range exceeded due to switching on 4 max Make sure platform empty Err 5 Key...

Страница 20: ...roval setting error Check the PCB jumper settings Must be connect jumper pin to K1 BW series ol Over range Remove the load Re calibrate lo Underload Minus weight check the platform and restart or cali...

Страница 21: ...ck the following voltages AC Power Check the AC power socket out put voltage Adaptor Voltage Check the adaptor output cable connecter voltage Compare the value with the name plate on the scale PCB Inp...

Страница 22: ...e Air variation or any vibrations Temperature changed Load cell or connections faulty Power supply faulty Check the scale is in acceptable location Check the connecters and load cell Check the power s...

Страница 23: ...er the main board lie on top cover use cross screw driver loose 4 screw for main board pull out all connector on the main board then you can bring out main board carefully Install the new main board p...

Страница 24: ...24 MPE_HNM MPE_PNM SH e 1810 10 DRAWING 10 1 MPE_HM...

Отзывы: