![KERN HFC Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/kern/hfc/hfc_service-manual_1957273032.webp)
32
HFC-SH-e-1510
10.2 Regular maintenance and care
The regular 3-month maintenance may only be carried out by an expert with
competent knowledge of working with suspended balances. Thereby the national
regulations for prevention of accidents as well as the working, operation and
safety regulations of the owner-operator.
To check the dimensions only use suitable test devices.
The regular 12-month maintenance must only be carried out by trained
specialized staff (KERN customer service).
The results of the maintenance must be written down in a checklist
The additional results of the extended maintenance have to be entered in the
checklist
The load suspension device is to be cleaned before inspection
Regular maintenance:
Prior to each usage
Check for fault-free operation of the attachment devices
Initial start-up
,
every
3 months
or
definitely after
12 500 weighing
processes
Check all dimensions
Check the suspended balance and the used attachment device
for wear and tear, such as e.g. plastic deformation, mechanical
damage (unevenness), notches, striation, cracks, corrosion and
torsions.
Remove balance from use immediately if a reading exceeds the
permitted deviation from the original reading or any other fault is
identified.
Every
12 months
or
in any case after
50 000 weighing
processes
If the enhanced maintenance has to be carried out by trained staff
(KERN customer service). At this general revision all load carrying
parts must be checked for gaps with magnetic powder.
Every
10 years
or
anyway after
500 000
weighing processes
Replace entire suspended balance
Note
For inspection of wear and tear please refer to the drawing below.
Rejection criteria:
Load carrying devices may no longer be used when e.g.
+
Deviations during the tests defined for maintenance were discovered.
+
The type or load rating plate is missing.
+
Load suspension devices known to have been overloaded or subject to other
harmful influences may no longer be used and/or may be re-used only after
inspection.
Содержание HFC
Страница 5: ...HFC SH e 1510 5 3 Technical data 3 1 Dimensions Balance 0 6 t 1 t Balance 3 t...
Страница 6: ...6 HFC SH e 1510 Balance 5 t Balance 10 t...
Страница 7: ...HFC SH e 1510 7 Holding strap terminal...
Страница 11: ...HFC SH e 1510 11 5 Appliance overview 5 1 Rear Battery or rechargeable battery compartment Mains connection...
Страница 22: ...22 HFC SH e 1510 Do not push or pull Do not pull the hook horizontally Do not use multiple suspensions...