3  Basic Information (General) 

3.1  Proper use 

The balance you purchased is intended to determine the weighing value of material 
to  be  weighed. 

It  is  intended  to  be  used  as  a  “non-automatic  balcance”,  i.e.  the 

material to be weighed is manually and carefully placed in the centre of the weighing 
pan.. As soon as a stable weighing value is reached the weighing value can be read. 

3.2  Improper Use 

Do  not  use  balance  for  dynamic  weighing.  In  the  event  that  small  quantities  are 
removed  or  added  to  the  material  to  be  weighed,  incorrect  weighing  results  can  be 
displayed due to the “stability compensation“. (Example: Slowly draining fluids from a 
container on the balance.) 
Do not leave permanent load on the weighing pan. This may damage the measuring 
system. 
Impacts and overloading exceeding the stated maximum load (max) of the balance, 
minus  a  possibly  existing  tare  load,  must  be  strictly  avoided.  Balance  may  be 
damage by this. 
Never operate balance in explosive environment. The serial version is not explosion 
protected. 
The  structure  of  the  balance  may  not  be  modified.  This  may  lead  to  incorrect 
weighing results, safety-related faults and destruction of the balance. 
The balance may only be used according to the described conditions. Other areas of 
use must be released by KERN in writing. 

3.3  Warranty 

Warranty claims shall be voided in case 

Our conditions in the operation manual are ignored 

The appliance is used outside the described uses 

The appliance is modified or opened 

mechanical damage and damage caused by media, liquids, 

natural wear and tear 

The appliance is improperly set up or incorrectly electrically connected 

The measuring system is overloaded 

EOA-BA-e-1310 

Содержание EOA 10K-3

Страница 1: ...mbH Ziegelei 1 Phone 49 0 7433 9933 0 D 72336 Balingen Fax 49 0 7433 9933 149 E Mail info kern sohn com Internet www kern sohn com Návod na obsluhu EN Balíková váha KERN EOA SK Version 1 0 10 2013 GB EOA BA e 1310 ...

Страница 2: ...e 7 5 1 Testing upon acceptance 7 5 2 Packaging return transport 7 6 Unpacking Setup and Commissioning 8 6 1 Installation Site Location of Use 8 6 2 Unpacking 8 6 2 1 Placing 8 6 2 2 Scope of delivery 9 6 2 3 Basic structure 9 6 3 Battery operation Standard 9 6 4 Mains connection optional 9 6 5 Initial Commissioning 9 6 6 Adjustment 10 6 7 Adjustment 10 7 Operation 11 7 1 Keyboard overview 11 7 2 ...

Страница 3: ...rm up time 10 minutes Weighing Units kg Recommended adjustment weight not added class 10 kg M2 20 kg M2 Stabilization time typical 3 sec Operating temperature 10 C 35 C Humidity of air max 80 not condensing Weighing plate mm 315 x 305 Electric Supply Input Voltage 15 V 600 mA Battery 9 V block Operating period 60 h Auto off 3 minutes Weight kg net 3 EOA BA e 1310 3 ...

Страница 4: ... 10 minutes Weighing Units kg Recommended adjustment weight not added class 40 kg M1 100 kg M1 Stabilization time typical 3 sec Operating temperature 10 C 35 C Humidity of air max 80 not condensing Weighing plate mm 315 x 305 Electric Supply Input Voltage 15 V 600 mA Battery 9 V block Operating period 60 h Auto off 3 minutes Weight kg net 3 4 EOA BA e 1310 ...

Страница 5: ...le produit auquel se rapporte la F conformité présente déclaration est conforme aux normes citées ci après Dichiarazione di Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si conformitá riferisce è conforme alle norme di seguito citate Conformiteit Wij verklaren hiermede dat het product waarop deze verklaring betrekking NL verklaring heeft met de hierna vermelde normen overe...

Страница 6: ...ing system Impacts and overloading exceeding the stated maximum load max of the balance minus a possibly existing tare load must be strictly avoided Balance may be damage by this Never operate balance in explosive environment The serial version is not explosion protected The structure of the balance may not be modified This may lead to incorrect weighing results safety related faults and destructi...

Страница 7: ...fully read this operation manual before setup and commissioning even if you are already familiar with KERN balances All language versions contain a non binding translation The original German is binding 4 2 Personnel training The appliance may only be operated and maintained by trained personnel 5 Transport and storage 5 1 Testing upon acceptance When receiving the appliance please check packaging...

Страница 8: ...xtreme dampness for longer periods of time Non permitted condensation condensation of air humidity on the appliance may occur if a cold appliance is taken to a considerably warmer environment In this case acclimatize the disconnected appliance for ca 2 hours at room temperature Avoid static charging of the material to be weighed weighing container and windshield Major display deviations incorrect ...

Страница 9: ...for a longer time take out the batteries and store them separately Leaking battery liquid could damage the balance 6 4 Mains connection optional Power is supplied via the external mains adapter The stated voltage value must be the same as the local voltage Only use original KERN mains adapters Using other makes requires consent by KERN 6 5 Initial Commissioning In order to obtain exact results wit...

Страница 10: ...hts of different nominal values may be used for adjustment but are not optimal for technical measuring Procedure when adjusting Observe stable environmental conditions A warming up time see chapter 1 is required for stabilization Operation Display Start balance by pressing Await zero display Press and keep it pressed CAL is displayed After approx 5 seconds appears automatically the size of the rec...

Страница 11: ...7 Operation 7 1 Keyboard overview Button Description Function ON OFF button Switch on off balance TARE button short pressing Tare balance long pressing Invoke adjustment EOA BA e 1310 11 ...

Страница 12: ...Place the tare vessel ex 3kg on the weighing plate example and press the button The balance display goes to 0 Put the sample into the tare vessel Weight of sample is indicated example If after finishing the weighing process the button is pressed again 0 appears anew in the display The taring process can be repeated any number of times e g when adding several components for a mixture adding The lim...

Страница 13: ...ple to 0 using the button Remove the nominal weight The nominal weight appears as negative display example Put the test objects subsequently on the weighing plate the respective deviation from the nominal weight is displayed with the respective sign to and example Back to weighing mode by pressing the button and with unloaded weighing plate EOA BA e 1310 13 ...

Страница 14: ...that no liquid penetrates into the device Polish with a dry soft cloth Spilled weighing goods must be removed immediately 8 2 Servicing maintenance The appliance may only be opened by trained service technicians who are authorized by KERN Before opening disconnect from power supply 8 3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regio...

Страница 15: ...wer supply interrupted Batteries are inserted incorrectly or empty No batteries inserted Draught air movement Table floor vibrations The weighing plate is in contact with foreign matter Electromagnetic fields static charging choose different location switch off interfering device if possible The display of the balance is not at zero Adjustment is no longer correct Great fluctuations in temperature...

Отзывы: