ECB-BA-e-0713

 

5

2  Declaration of conformty 

 

KERN & Sohn GmbH 

D-72322 Balingen-Frommern 
Postfach 4052 
E-Mail: [email protected] 

Tel: 0049-[0]7433- 9933-0 
Fax: 0049-[0]7433-9933-149 
Internet: www.kern-sohn.de 

 

Konformitätserklärung 

 

Declaration of conformity for apparatus with CE mark 

Konformitätserklärung für Geräte mit CE-Zeichen 

Déclaration de conformité pour appareils portant la marque CE 

Declaración de conformidad para aparatos con disitintivo CE 

Dichiarazione di cofnromitá per apparecchi contrassegnati con la marcatura CE

 

 

English 

We hereby declare that the product to which this declaration refers conforms with the fol-
lowing standards.  

Deutsch 

Wir erklären hiermit, daß das Produkt, auf das sich diese Erklärung bezieht, mit den nach-
stehenden Normen übereinstimmt.  

Français 

Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente 
déclaration, est conforme aux normes citées ci-après.  

Español 

Manifestamos en la presente que el producto al que se refiere esta declaración est´´a de 
acuerdo con las normas siguientes 

Italiano 

Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è confor-
me alle norme di seguito citate.  

 

Electronic Parcel Scale: 

KERN ECB 

 

Mark applied 

EU Directive 

Standards 

 

89/336EEC EMC 

EN 61000-3-2 :1995+A1&A2 : 1998 
EN 61000-3-3 :1995 
EN 50081-1 (EN 55022) : 1992 
EN 50082-1 (EN 61000-4-2) : 1997 
EN 50082-1 (EN 61000-4-3) : 1997 
EN 50082-1 (ENV 50204) : 1997 
EN 50082-1 (EN 61000-4-4) : 1997 
EN 50082-1 (EN 61000-4-6) : 1997 
EN 50082-1 (EN 61000-4-5) : 1997 
EN 50082-1 (EN 61000-4-11) : 1997

 

 

 

 

 

Date: 12.12.2002 

Signature:

 

 

 

 

Gottl. KERN & Sohn GmbH 

 

 

 

 

Management 

 

 

 

 

 

Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0,Fax +49-[0]7433/9933-149

 

 

 

 

Содержание ECB

Страница 1: ...mbH Ziegelei 1 D 72336 Balingen E Mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating instruction Platform scale KERN ECB Version 1 3 05 2007 GB EC...

Страница 2: ...installation and commissioning _________________________ 8 6 1 Place of installation place of use ____________________________________ 8 6 2 Unpacking the Balance _____________________________________...

Страница 3: ...________________________________ 17 8 1 Cleaning _______________________________________________________ 17 8 2 Maintenance upkeep _____________________________________________ 17 8 3 Disposal________...

Страница 4: ...ing range subtractive 10 kg 20 kg 50 kg Reproducibility 10 g 20 g 50 g Linearity 20 g 40 g 100 g Adjustment tolerance as per M3 5 kg 10 kg 20 kg Stabilisation time typical 2 3 sec Optimal temp of oper...

Страница 5: ...n Normen bereinstimmt Fran ais Nous d clarons avec cela responsabilit que le produit auquel se rapporte la pr sente d claration est conforme aux normes cit es ci apr s Espa ol Manifestamos en la prese...

Страница 6: ...ing equipment Be sure to avoid impact shock and overloading the balance in excess of the pre scribed maximum load rating max minus any possible tare weight that is already present This could cause da...

Страница 7: ...mal 4 Fundamental safety information 4 1 Observe the information in the operating instructions Please read the operating instructions carefully before erecting and commissioning even if you already ha...

Страница 8: ...rs and dust Do not expose the device to extreme dampness for longer periods of time In admissible bedewing condensation of air moisture on the device can occur if a cold device is taken into a signifi...

Страница 9: ...Insert 6 x 1 5volt AA batte ries Replace the battery cover To preserve battery life the balance switches off automatically after 3 minutes if no weighing has taken place For battery operation the bala...

Страница 10: ...ECB BA e 0713 10 Rechargeable Battery Installation 1 Remove battery cover 2 Slide spacer to left or right lever down on corner then remove the spacer 3 Insert and connect rechargeable battery...

Страница 11: ...alance periodically during weighing operation in order to obtain exact measured values 6 6 Adjusting Using a precision weight the accuracy of the balance can be checked at any time and adjusted Adjust...

Страница 12: ...heavier than the weighing range the display indicates E Overload The balance is switched off by pressing the ON OFF key once 7 2 Taring Switch the balance with the ON OFF key on and wait until displa...

Страница 13: ...ew Keep both keys pressed until in the display bl appears Release both keys The balance is situated in the menu Press the ON OFF key until bl appears Confirm with the TARE key Press the ON OFF key to...

Страница 14: ...h switched off Zero Tracking the display however is more unstably Activate deactivate Zero Tracking When the balance is switched off press the TARE key and keep it pressed Do not release the TARE key...

Страница 15: ...it pressed Keep the ON OFF key pressed however release the TARE key Press TARE key anew Keep both keys pressed until in the display bl appears Release both keys The balance is situated in the menu Pre...

Страница 16: ...wever release the TARE key Press TARE key anew Keep both keys pressed until in the display bl appears Release both keys The balance is situated in the menu Press the ON OFF key until rSt appears Confi...

Страница 17: ...and rub off using a clean soft cloth Loose sample residue powder can be removed carefully using a brush or hand vac uum cleaner Remove any spilt material to be weighed immediately 8 2 Maintenance upk...

Страница 18: ...The weight display changes continu ally Draught air movement Table floor vibrations The weighing plate is in contact with for eign matter Electromagnetic fields static charging choose different locati...