6.
机械
性
能
Physical Characteristics
耐冲击
性
6.1
实验
项目
Item
实验
条件
Test Condition
实验后
规格
Specification
峰值加速
度
980m/s
2
,
半正弦
波
,
XYZ
三个方
向各
3
次冲击实验后
,
测试
声响器
.
Sounder shall be measured after being applied
shock(980m/s
2
) for each three mutually
perpendicular directions to each of 3 times by half
sine wave.
耐振动
性
Sounder shall be measured after being applied
vibration of amplitude of 1.5mm with 10 to55Hz band of
vibration frequency to each of 3 perpendicular directions
for 2 hours.
振动频率
10
~
55 Hz,1.5mm
全振幅
,XYZ
三
个方向各
2
小时试验后
,
测试
声响器
.
6.2
6.3
耐
焊
接
性
将声响器的
插针插
入
(
插至距
声响器
壳体
1.5mm
处为止
) +350
±
5
℃的焊
锡槽
3
±
0.5
秒
或
+260
±
5
℃的焊
锡槽
10
±
1
秒
,
然后
在常温中
放置
4
小时后
,
测试
声响器
.
Lead terminal are immersed up to 1.5mm from
sounder's body in solder bath of +350
±
5
℃
for 3
±
0.5
seconds or
±
260
±
5
℃
for 10
±
1 seconds, and then
sounder shall be measured after being placed in natural
condition for 4hours.
Shock
Vibration
Resistant
Soldering Heat
Resistance
6.4
可
焊性
Solderability
Lead terminals are immersed in rosin for 5
seconds and then immersed in solder bath
of +260
±
5
℃
for 3
±
0.5 seconds.
先
将声响器的
插针浸
入
松香液
5
秒钟
,
然后浸
入
+260
±
5
℃
熔融
的
锡槽
中
3
±
0.5
秒
.
6.5
插针强
度
分别
在
每个插针
的
轴向施加
9.8
牛顿
的
静荷
重
10
秒
.
The force 10 seconds of 9.8N is applied to
each terminal in axial direction.
Terminal
Strength Pulling
符合
表
1
的
要
求
The measured
value shall meet
Table 1.
插针表
面
90%
以
上
被
焊
锡
润
湿
.(
插
针
的
段面除外
)
90% min. lead
terminals shall be
wet with solder.
(Except the edge
of terminal)
插针没
有
断开和
可见
的
损伤
No visible
damage and
cutting off
Drawing No.OEM1824SPC
P. 3/10
No.25 Baoyuan road Dongqian Lake, Industry Area, Dongqian town,Ningbo City,China(Post Code:315121)
E-Mail: [email protected]
宁波凯普电子有限公司
http://www.chinaacoustic.com
Ningbo Kepo Electronics Co.,Ltd.