BROWNOUT VOLTAGE:  

115V a-c input selection, 80V a-c min. (85V a-c min. for model RAX 28-6.2K) 

230V a-c input selection, 160V a-c min. (170V a-c min. for model RAX 28-6.2K) 

320V d-c input selection, 220V d-c min. (Jumper in 230V a-c position)

INPUT CURRENT: 

 (maximum load at 50°C with nominal output voltage):

INPUT PROTECTION AND SOFT START:  

A triac soft start circuit reduces start-up surge. Units are protected against

shorts by an input fuse. Fuse value 6.3A.

INPUT SURGE:  

At 25°C from cold start:

NOTE: There are two input surges at turn-on:

EFFICIENCY:  

75% typical (79% typical for model RAX 3.3-35K)

STABILIZATION: 

TRANSIENT RECOVERY: 

 A step load change from 50% to 100% of rated load current in 50 microseconds or more, pro-

duces no more than 4% output voltage excursion. Recovery to 1% of the original voltage is less than 1 millisecond.

OUTPUT HOLDING TIME: 

Output is maintained for 20 milliseconds minimum upon input interruption (30 milliseconds typi-

cal) with nominal input voltage and output load at 50°C current rating.

OVERVOLTAGE PROTECTION:  

Fixed, factory set. See Table 1. The overvoltage circuit is reset by interrupting input for

approximately 15 seconds.

OPERATING TEMPERATURE:   

0 -71°C. See the derating graph, Figure 1.

STORAGE TEMPERATURE:   

-20°C to + 75°C.

HUMIDITY: 

 20% to 95% relative humidity, noncondensing  

ISOLATION:  

(at 25°C ambient, 65% relative humidity):

Between input and output terminals, 3.75 KV a-c for 1 minute (with Y-capacitors removed). 

Between input and output or chassis, 2000V a-c for 1 minute. 

Between output terminals and chassis, 500V a-c for 1 minute.

INSULATION RESISTANCE: 

 Between output and chassis, 100 megohms minimum (500V d-c)

LEAKAGE CURRENT: 

0.5mA max at 120V a-c (U.L. Method) 

0.75mA max at 240V d-c (U.L./VDE Method)

VIBRATION: 

Three Axes: 

5-10 Hz., 10 mm amplitude 

10-55 Hz., 2g

SHOCK:  

Three axes, 20g, 11 ms ±5msec pulse duration

INPUT SOURCE

NOMINAL INPUT VOLTAGE

MINIMUM INPUT VOLTAGE

120 V a-c input selection 

3.4A typ. - 4.2A max.

3.8A typ. - 4.4A max.

220-240V a-c input selec-
tion 

1.7A typ. - 2.2A max.

2.1A typ. - 2.3A max.

d-c input selection 

1.2A max. (320V input)

1.5A max. (220V input)

INPUT SOURCE

FIRST SURGE (5ms max.)

SECOND SURGE (3ms max.)

120 V a-c input selection 

17A max.

20A typ.

220-240V a-c input selec-
tion 

34A max.

15A typ.

320V d-c input selection 

34A max.

34A typ.

CHARACTERISTIC

TYPICAL

MAXIMUM

Source Effect (min  - max)

 0.8%

1.5%

Load Effect, measured at sensing terminals (10%  - 100% load change)

 0.8%

1.5%

Temperature effect (0 to 71°C)

1.0%

2.0% 

Combined effect (envelope)

2.0%

4.0%

Drift (8 hr. at 25°C)

0.1% 

0.5%