3. INSTALLATION INSTRUCTIONS, RA 81-1
3.1 MATERIAL REQUIRED
(See Table 1.)
3.2 INSTALLATION PROCEDURE
Refer to Figure 1 and proceed as follows:
1.
On one side of the unit, mount one L-type bracket with knob (supplied with unit) to the unit using two screws
supplied with unit (see Figure 1).
2.
Mount the U-type bracket supplied in the Kit to the other side of the unit using two screws supplied in Kit.
3.
Mount the other L-type bracket with knob (supplied with unit) to the end of the U-type bracket using two screws
supplied with unit. The knobs attached to the L-brackets can now be used to support the assembled unit while
installing in a 19-inch rack.
FIGURE 1. RA 81-1, INSTALLATION
TABLE 1. MATERIAL REQUIRED, RA 81-1
MATERIAL
Location
QUANTITY
L bracket with knob
Supplied with unit
2
Screws to mount L bracket
Supplied with unit
4
U bracket
Supplied with RA 81-1
1
Screws to mount U bracket, M4, Flat head, CSK
Supplied with RA 81-1
4