6.0 GENERAL SPECIFICATIONS (SEE TABLE 5)
TABLE 4. OUTPUT SPECIFICATIONS
Parameter
Specification
MIN
MAX
TYP UNIT
Output Voltage (Over All Operating Input Voltage,
Resistive Load, And Temperature Conditions)
4.75
6.25
Vdc
Output Voltage Setpoint (V
I
=48 volts, I
o=
I
o
max,
T
A
=25°C.
Unit Operating In Parallel Or Parallel Pin Shorted
To Sense (-) Pin (See Figure 3)
Parallel Pin Open
4.9
4.9
5.1
6.25
500
5.00
Vdc
Vdc
Output Short Circuit Current
51.0
40.5
A
Output Current Limit Inception
30.9
39.0
A
Output Current
30.0
A
Output Regulation : Line Vi= 36 to 72 Volts
Load Io= 1.0A to I
o
max
Temperature -T
A
=0°C° to 90°C
02%
0.05%
%
0.4%
0.2%
%
50
50
mV
TABLE 5. GENERAL SPECIFICATIONS
Parameter
Specification
Case Temperature (min-max)
Operating: 0° to 90°C
Storage: -40°C to 125°C
Isolation Resistance
10M Ohms Minimum
Isolation Capacitance
1700 pF Typical
I/O Isolation Voltage
500 Vdc Maximum
Calculated MTBF
(at 80% of I
o
,
max ,
T = 40°C)
920000 Hours
Dimensions
0.66(16.8) X 4.8(121.9) X 2.5(63.5)
See Mechanical Outline Drawing, Figure 3
Weight
7.0 OZS (198.45 Grams) Maximum
Cover Material
Non- Conductive Material
Содержание KFD 6-25-60W
Страница 2: ......
Страница 17: ...KFD 6 25 60 060801 13 FIGURE 3 MECHANICAL OUTLINE DRAWING OF THE SINGLE OUT PUT KFD DC TO DC CONVERTER...
Страница 20: ...16 KFD 6 25 60 060801 FIGURE 6 CIRCUIT CONFIGURATION FOR SINGLE KFD DC TO DC CONVERTER REMOTE SENSE OPERATION...
Страница 25: ...KFD 6 25 60 060801 21 FIGURE 12 HEAT SINK DERATING CURVES NATURAL CONVECTION FINS ORIENTED ALONG THE WIDTH...
Страница 26: ...22 KFD 6 25 60 060801 FIGURE 13 HEAT SINK DERATING CURVES NATURAL CONVECTION FINS ORIENTED ALONG THE LENGTH...
Страница 28: ......