KEPCO HSF-1UR 50W Series Скачать руководство пользователя страница 6

6

228-1563 REV 10

 083013

KEPCO, INC. 

   

 131-38 SANFORD AVENUE 

 

  FLUSHING, NY. 11355 U.S.A.

 

  TEL (718) 461-7000

   

 FAX (718) 767-1102

  

http://www.kepcopower.com   

 

 email: [email protected]

FUSE:  

-1UR:  Quick acting 3.0A, 250V; (5.2 x 20mm), 

San-O P/N MT4 3A; Kepco P/N 541-0110.

T, C, X, Y Models:Wickmann P/N C1-372-2.0A, 

Kepco P/N 541-0136.

DIMENSIONS:  

See Figure 7.

WEIGHT:   

 -1UR Models: 1.5Lbs (0.7Kg); 

T, C, X and Y Models: 1.25Lbs (0.57Kg).

WARRANTY:  

5 years.

FIGURE 5.  % OUTPUT POWER RATING VS. 

AMBIENT TEMPERATURE

IV — INSTALLATION

MOUNTING THE POWER SUPPLY.  

Refer to Figure

6 and insert HSF-1UR power supply in selected slot until
power supply front panel is flush with rack adapter chassis
and secure with two front panel mounting screws. 

CAUTION: Do not overtighten these screws: max.
torque is 2 in.-lbs. (0.23 N x m).

CONNECTIONS. 

All connections are made at the rear

panel of the RA 19-1U Rack Adapter (see RA 19-1U
Operator Manual). Connect the load to the applicable ±
DC OUTPUT terminals. AC input power is applied via two
INPUT POWER terminal blocks: one supplying slots 2
and 4, the other supplying slots 1 and 3. Make sure to

connect the AC input Neutral, Line and Ground wires to
the respective terminals of the terminal blocks.

REMOVAL. 

To remove a power supply, first use the

POWER switch to turn off the unit. Then loosen the two
mounting screws and extract the unit from the RA 19-1U
Rack Adapter. 

CAUTION: The ON/OFF switch must be

set to OFF before removing the unit from the rack
adapter

.

V — OPERATION     

Turn the unit on using the front panel POWER switch (see
Figure 6). 

CAUTION: DO NOT repeatedly toggle the

POWER on/off switch as this may cause unit to fault.

When output voltage is available, the VDC ON LED is on
(green). All 50W models use convection cooling and do
not include a fan.

While monitoring output voltage at the front panel test
points, the Output Voltage Adjust trimmer allows adjust-
ment of the output voltage. 

The 3.3V models do not use forced current sharing so the
MASTER ON LED is always off. The MASTER ON LED
for 5V through 48V models goes on under any of the three
following conditions:

• Independent operation.

• Operation in a parallel master/slave configuration

to indicate which unit is the master.

• Operation in a parallel master/slave configuration

to indicate that a slave unit is no longer within the
proper specifications for paralleled units. Slave 1
should be optimally adjusted to 40mV less than
master, slave 2 adjusted to 40mV less than slave
1, etc. The maximum allowable difference
between paralleled units is 250mv. The minimum
allowable difference between paralleled units is
25mV. If a slave exceeds these limits, the MAS-
TER ON light goes on.

FIGURE 6.  COMPONENT LOCATIONS

NOTE:
Safety agency approvals apply only to operation up to 40°C.

3043412

POWER 
SWITCH

TEST 

POINTS

VOLTAGE 

ADJUST

TRIMMER

MASTER

ON

LED

VDC 

ON

LED

MOUNTING

SCREW

MOUNTING

SCREW

NOTE:  MOUNTING SCREW MAX TORQUE: 2 IN.-LBS. (0.23 N x m)

Содержание HSF-1UR 50W Series

Страница 1: ...od els is a Kepco RKW power supply 28V model not avail able T option 1URT models use a Kepco RTW power supply instead of the RKW T option models weigh less and have improved efficiency input current specifications All volt ages are available C option 1URC models include a current sensing resis tor allowing external current monitoring within 10 con tact Kepco if greater accuracy required In additio...

Страница 2: ...T CURRENT NOMINAL 3 10A 10A 4 3A 3 5A 2 2A 3 2A Peak 8 1 8A 1 1A CURRENT LIMIT 4 10 5A min 10 5A min 4 5A min 3 68A min 3 3A 2 3A 9 min 1 9A min 1 15A min OUTPUT POWER MAX 5 33W 50W 51 6W 52 5W 52 8W 50 4W 52 8W SHORT CIRCUIT CURRENT 4 15A 15 5 9 12 6A 5 6A 5 4A 4 5 9 3A 9 2 5A 2 4A 1 7A 9 RIPPLE AND NOISE mV p p 0 40 C 10 100 LOAD switching typ 80 80 100 100 100 150 200 spike noise d c 50MHz 120 ...

Страница 3: ... drop across REQ is measured across IMON pins requires millivoltmeter range 0 to 250mV Accuracy is 10 contact Kepco if greater accuracy is required There is no isolation between IMON alarm circuit and d c out put Refer to the applicable RA 19 1U Manual for details ALARM CIRCUIT The HSF 1UR includes an isolated internal relay offering normally closed and normally open contacts referenced to an isol...

Страница 4: ...indicates that forced current share is no longer work ing units are simply in current share mode If forced cur rent sharing at less than 10 nominal current per supply is needed contact Kepco application engineering Remote sensing is recommended For master slave oper ation to work properly each unit should be adjusted to 40 mV optimum less than the next paralleled unit unit 1 is adjusted to VOUT un...

Страница 5: ...ces less than 4 output excursion Recovery occurs to within 1 of the original setting in 2 ms load change tr or tf equal to or greater than 50µsec START UP TIME 500 ms maximum HOLDUP TIME 1UR 20 ms typ 120V a c 15 ms min 100V a c Options T C X and Y all except 3 3V and 28V mod els 30ms typ 20ms min Options T C X and Y 3 3V model 55ms typ 40ms min Options T C X and Y 28V model 35ms typ 25ms min DIEL...

Страница 6: ... Adapter CAUTION The ON OFF switch must be set to OFF before removing the unit from the rack adapter V OPERATION Turn the unit on using the front panel POWER switch see Figure 6 CAUTION DO NOT repeatedly toggle the POWER on off switch as this may cause unit to fault When output voltage is available the VDC ON LED is on green All 50W models use convection cooling and do not include a fan While moni...

Страница 7: ...MENSIONS ARE IN INCHES DIMENSIONS IN BRACKETS ARE IN MILLIMETERS FRONT PANEL KEPCO DUAL TONE GRAY C FRONT PANEL 0 090 THK ALUM 6061 T6 A BACKPLATE 0 064 THK ALUM 5052 H32 3 MODULE IS KEYED AS SHOWN IN DETAIL 0 591 15 0 1 MATERIAL B PCB 0 063 THK FR 4 2 FINISH KEY PIN LOCATION 48 VOLTS 28 VOLTS 24 VOLTS 15 VOLTS 5 VOLTS 3 3 VOLTS 12 VOLTS 0 129 3 3 3 755 95 4 0 303 7 7 0 690 17 5 4 275 108 6 0 260 ...

Отзывы: