background image

IMPORTANT NOTES:

1)

This manual is valid for the following Model and associated serial numbers:

MODEL

SERIAL NO.

REV. NO.

2)

A Change Page may be included at the end of the manual. All applicable changes and
revision number changes are documented with reference to the equipment serial num-
bers. Before using this Instruction Manual, check your equipment serial number to identify
your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu-
mentation Office in New York, (718) 461-7000, requesting the correct revision for your
particular model and serial number.

 
3)

The contents of this manual are protected by copyright. Reproduction of any part can be
made only with the specific written permission of Kepco, Inc. 

 
 

Data subject to change without notice.

KEPCO

®

  

THE POWER SUPPLIER™

MODEL

O P E R ATO R ’ S   M A N U A L

KEPCO INC.

KEPCO, INC.  

  131-38 SANFORD AVENUE  

  FLUSHING, NY. 11355 U.S.A.  

  TEL (718) 461-7000  

  FAX (718) 767-1102

email: [email protected]  

  World Wide Web: http://www.kepcopower.com

An ISO 9001 Company.

HSF 600 Watts

©2015, KEPCO, INC
P/N 228-1588-R

 

 

HSF 600 WATTS

 POWER SUPPLY

HSF 600 WATTS

POWER SUPPLY

SINGLE OUTPUT POWER SUPPLIES

SINGLE PHASE, POWER FACTOR CORRECTED

UNIVERSAL AC INPUT

HSF 12-53, HSF 15-43, HSF 24-27, 

HSF 28-23, HSF 48-13

HSF 12-53C, HSF 15-43C, HSF 24-27C, 

HSF 28-23C, HSF 48-13C

Содержание HSF 12-53

Страница 1: ...rticular model and serial number 3 The contents of this manual are protected by copyright Reproduction of any part can be made only with the specific written permission of Kepco Inc Data subject to ch...

Страница 2: ...ote Sensing 13 3 9 Retaining Latches 13 4 Load Connection 14 5 Connecting Multiple Power Supplies 14 5 1 Adjusting the Voltage 14 5 2 Parallel Connections Standard and C Models 14 1 HSF Rear Panel Con...

Страница 3: ...pco s Series RA 19 4C rack adapters The RA 19 4C rack adapter accepts up to four 600W modules All input output connections are through a 24 pin connector that plugs in to the rack adapter All external...

Страница 4: ...COM 14 Common contact of alarm relay see PAR 3 7 2 REF 15 Reference voltage When used with RV pin 18 allows all output voltages of paralleled slave supplies to be controlled by one voltage adjustment...

Страница 5: ...Factor typ AC Input 100V 0 99 0 99 0 99 0 99 0 99 AC Input 200V 0 95 0 95 0 95 0 95 0 95 Ripple Noise 6 mV p p ripple 180 180 220 220 220 ripple noise 220 220 320 320 320 Sense Resistor IMON values Oh...

Страница 6: ...1000 3 2 0 95 typical 200V a c max load nominal output per EN 61000 3 2 Transient Recovery excursion characteristic 4 maximum 50 to 100 load transient time 50 sec recovery time 1 ms maximum Stabilizat...

Страница 7: ...2 No 60950 1 03 1st Edition 2006 07 EN 60950 RoHS Compliance Contact Kepco Sales for further information EMC Emission Conducted Designed to meet FCC Class B VCCI Class B EN55011 B EN55022 B EMC Emissi...

Страница 8: ...e controlled either by the front panel Vadj control or by remote control using either an external trimpot or voltage source see PAR 3 4 4 288 108 9 5 218 132 5 1 500 38 1 0 093 2 4 14 667 372 5 5 040...

Страница 9: ...eatedly toggle the power ON OFF switch as this may cause unit to fault NOTE The ON OFF switch must be set to OFF before removing unit from rack adapter If remote on off is not enabled see PAR 3 5 the...

Страница 10: ...d in Table 2 see PAR 3 4 1 Not functional if remote voltage control is enabled see PAR 3 4 2 3 DC output test points Connect to voltmeter to monitor output voltage 4 OUTPUT RESET switch Used to recycl...

Страница 11: ...shown in Figure 7A Suggested value for the trim mer control is 5K ohms Referring to Figure 7 A Resistor R is used to obtain minimum output voltage required to ensure proper operation of the alarm rel...

Страница 12: ...DC output pins and a c input terminals FIGURE 8 DIP SWITCH SETTINGS FOR USING RESET BUTTON OR REMOTE ON OFF 3 6 PROTECTION CIRCUITS The following protection features are implemented in the HSF 600W Se...

Страница 13: ...the OUTPUT RESET switch on the front panel or if the remote on off feature is in use see PAR 3 5 open the connection between the RC pins and then reconnect the pins The unit may also be restarted by t...

Страница 14: ...he rack adapter I O connector and PF pin 13 provided directly from the Kepco RKW power supply that is the heart of the HSF This option is selected by setting positions 5 and 6 of the DIP switches as s...

Страница 15: ...5 These latches work in conjunction with the RA 19 4C rack adapters to prevent unauthorized or inadvertent module extraction from an operating power system The latch is engaged by loosening the cap he...

Страница 16: ...xcept one designated as the master and adjust to desired voltage using the front page trimmer and monitoring the front panel voltmeter Each slave must be adjusted to a slightly lower voltage than the...

Отзывы: