IV — SPECIFICATIONS (C, T, X, Y) - CONTINUED

STABILIZATION: 

Source Effect (full load): 

Range: 90-132V a-c or 170-265V a-c

0.2% typ.; 0.3% max.

Load Effect (10% to 100% load change):

 0.5% typ.; 1.5% max.

Temperature Effect: 0.5% typ.; 1.0% max.

Range: –10° to 71°C

Combined Effect: 0.9% typ.; 1.8% max. (includes

source, load, and temperature effects).

Time Effect (1/2 hr-8 hr at 25°C): 

0.2% typ.; 0.5% max. 

RECOVERY CHARACTERISTICS:  

 A step load

change from 50% to 100% produces less than +4% output
excursion. Recovery occurs to 1% of the original
setting in <1 ms (load change t

or t

f

 equal to or greater

than 50

sec).

START-UP TIME:  

500 ms. max, 400 ms typ. (100V a-c)
300 ms. max, 200 ms typ. (240V a-c) 

HOLDUP TIME:  

30 ms. typ., 20 ms. min.

DIELECTRIC STRENGTH: 

Between input and output: 

2KV a-c for one minute

Between input and case (ground): 

2KV a-c for one minute.

Between output and case (ground):

[500V a-c for one minute, cutout current 20 mA]

INSULATION RESISTANCE: 

 Between input and

ground, output and ground, input and output:

100 Megohms min. (500V d-c).

LEAKAGE CURRENT  

0.45mA max. (IEC 950 and UL1950, 120V a-c)

0.6mA max. (IEC 950 and UL1950, 240V a-c).

SAFETY:  

Units are designed to meet UL60950 3rd [1st]

Edition, CSA 22.2 No. 60950 and EN 60950 and are CE
marked per the Low Voltage Directive (LVD), 73/23/EEC
and 93/68/EEC. The standards do not apply with DC input
operation.

EMI:  

Designed to meet FCC Class B (100-120V a-c) and

EN 50082-2.

VIBRATION:  

(non-operating, one hour on each one of

the three axes):

5-10 Hz, 10 mm amplitude.
10-55 Hz, 2g acceleration.

SHOCK:  

(non-operating, one-half sinusoidal pulse, three

shocks to each axis):

Acceleration: 60g 
Duration: 11ms +5ms

OPERATING TEMPERATURE:  

See Figure 4.

STORAGE TEMPERATURE:  

-30

o

C to +75

o

C.

RELATIVE HUMIDITY:  

Operating and storage: 

up to 95% (wet bulb temp. <35

o

C non-condensing).

FUSE:  

Slow Blow, 2A, 250V; (5 x 20 mm), 

Littelfuse, P/N 215002PG; 
Kepco P/N 541-0137.

DIMENSIONS:  

See Figure 6.

WARRANTY:  

5 years.

Содержание HSF 12-4.3PFC

Страница 1: ...d models and Section IV on page 6 suffix C T X and Y OPTIONS Options are identified by suffix T PFCT offers improved efficiency less weight and the addition of a 28V 50W model C PFCC offers current mo...

Страница 2: ...line ac input line failure etc results in an alarm All models include an isolated internal relay offering nor mally closed and normally open contacts referenced to an isolated common These contacts a...

Страница 3: ...each other and each unit must be operating at between 10 to 100 of rated output current If current to the load goes below 10 for each unit in cur rent share mode all MASTER ON lights may go on see loa...

Страница 4: ...typ 200 Va c 100 load Power Factor 0 99 typ 100V a c 0 95 typ 200V a c Switching Frequency 140KHz typical TABLE 1 OUTPUT RATINGS AND SPECIFICATIONS HSF PFC 50W SERIES STANDARD NO SUFFIX MODEL HSF 3 3...

Страница 5: ...c for one minute cutout current 20 mA INSULATION RESISTANCE Between input and ground output and ground input and output 100 Megohms min 500V d c LEAKAGE CURRENT 0 24 mA maximum IEC 950 and UL 1950 120...

Страница 6: ...1 PFCC PFCT PFCX PFCY HSF 12 4 3 1 PFCC PFCT PFCX PFCY HSF 15 3 5 1 PFCC PFCT PFCX PFCY HSF 24 2 2 1 PFCC PFCT PFCX PFCY HSF 28 1 8 1 PFCC PFCT PFCX PFCY HSF 48 1 1 1 PFCC PFCT PFCX PFCY OUTPUT VOLTS...

Страница 7: ...Between input and case ground 2KV a c for one minute Between output and case ground 500V a c for one minute cutout current 20 mA INSULATION RESISTANCE Between input and ground output and ground input...

Страница 8: ...fault FIGURE 5 COMPONENT LOCATIONS When output voltage is available the green VDC ON LED is on While monitoring output voltage at the front panel test points the Output Voltage Adjust trimmer allows...

Страница 9: ...ANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 www kepcopower com email hq kepcopower com 081721 228 1532 REV 16 9 FIGURE 6 HSF PFC 50W INCLUDING SUFFIX C T X AND Y POWER SUPP...

Отзывы: