background image

2

228-1158

 080502

KEPCO, INC. 

 " 

 131-38 SANFORD AVENUE 

 "

  FLUSHING, NY. 11352 U.S.A.

  "

  TEL (718) 461-7000

  " 

 FAX (718) 767-1102

  

http://www.kepcopower.com   

 email: [email protected]

HOLD-UP TIME:   

20 ms. typ. (120V a-c), 15 ms. min (100V a-c).

DIELECTRIC STRENGTH: 

 

Between input and output: 2KV a-c for one minute.

 Between input and output with Y-capacitor removed: 3.0KV a-c for one minute.

 Between input and case (ground): 2.0KV a-c for one minute.

INSULATION RESISTANCE: 

 Between input and ground, output and ground, input and output;

100 Megohms min. (500V d-c).

LEAKAGE CURRENT  

(UL method, 120V a-c, 50-60Hz, single terminal connection): 0.5 mA maximum.

(VDE method, 240V a-c, two terminal connection): 0.75 mA maximum.

SAFETY:  

UL 1950 recognized (ambient temperature 40° C maximum); CSA E.B. 1402C Level 3 Certified (FAW 48-2K Level 1 Certified);

IEC 950 Approved by TÜV Rheinland (based on EN 60950/09.87, ambient temperature 50° C max.) - cover removed.

(+) SENSE, (–) SENSE: 

See Figure 3. These terminals are provided to compensate for voltage drops in the load connecting wires. The

Sense terminals must be connected to their respective (+) and (–) output terminals, either at the load or at the Power Supply output termi-

nals. The connection ensures the most accurate error tracking. Error compensation in the connecting wires is up to 0.25 Volts for the FAW

5-20K model, and up to 0.4 Volts for all other models.

“POWER OK” SIGNAL OUTPUT: 

The unit supplies a “POWER OK”  logic 1 signal at CP51 (see Figure 2 and Figure 4, View “A”).

CONNECTOR TYPES:  

Refer to the Mechanical Outline Drawing. The mating connector for CP51 is a Panduit, P/N CT10F22-2: Cover,

P/N TC100F-2.

CONNECTOR KIT: 

Kepco furnishes an optional connector kit with the specified connector listed above. The kit may be ordered under

Kepco Model Kit P/N 518-0029. The connector is provided with 1 meter length leads for trimming to desired lengths.

EMI:  

Designed to meet FCC Class B (100-120V a-c) and VDE 0871 Class B (220-240V a-c).

VIBRATION:  

(non-operating, one hour on each one of the three axes):

5-10 Hz, 10 mm amplitude.

10-55 Hz, 2g acceleration.

SHOCK:  

(non-operating, one-half sinusoidal pulse, three shocks to each axis):

Acceleration: 20g 

Duration: 11ms +5ms

OPERATING TEMPERATURE:  

0 - 71° C (see Figure 1).

STORAGE TEMPERATURE:  

–40

o

C to +75

o

C.

OPERATING AND STORAGE RELATIVE HUMIDITY:  

up to 95% (wet bulb temp. <35

o

C non-condensing).

MOUNTING SCREW: 

No. 4-40 UNC Thread (see Figure 4)

MAXIMUM SCREW PENETRATION: 

0.197 in. (5mm) max.

WEIGHT: 

2.20 lbs. (1.0Kg max.), 3.31 lbs. (1.5 Kg max. with cover).

DIMENSIONS: 

3.74 in. (95mm) H x 1.38 in. (35mm) W x 7.87 in. (200 mm) L

CASE DIMENSIONS: 

3.74 in. (95mm) H x 1.50 in. (38mm) W x 7.87 in. (200 mm) L

FRAME MATERIAL:  

Aluminum

FUSE:  

Quick acting 5.0A, 250V; (5.2 x 20mm), San-O P/N EQ5.0A; Kepco P/N 541-0112.

WARRANTY:  

1 year.