3-16
BOPHV020411
programming. The current programming circuits are illustrated in FIGs. 3-16 to 3-22. Any excep-
tions with respect to current channel programming are noted on the diagrams.
NOTE: Adjust the “zero” output current point by means of the built-in “I
O
ZERO” control. Make
sure that the input of the BOP current channel is short-circuited to the ground signal.
FIGURE 3-16. REMOTE POTENTIOMETER CONTROL OF THE BOP OUTPUT CURRENT
FIGURE 3-17. REMOTE OUTPUT CURRENT CONTROL BY MEANS OF A TWO TERMINAL RESISTANCE