B-8
BIT 4886 051010
B.34 [SOURce:]LIST:DIRection COMMAND
LIST:DIR
Syntax:
Short Form: LIST:DIR (UP|DOWN)
Long Form: LIST:DIRection (UP|DOWN)
Description:
Allows the list to be executed from beginning to end (UP) or from end to the beginning
(DOWN).
*RST or LIST:CLEar sets the list to the UP direction (beginning to end)
.
Works with both
LIST:GEN DSEQ and LIST:GEN SEQ commands. Related Commands: LIST:GEN. LIST:SEQ,
LIST:DWEL?. (See example, Figures B-2 and B-3.)
B.35 [SOURce:]LIST:DIRection? QUERY
LIST:DIR?
Syntax:
Short Form: LIST:DIR?
Long Form: LIST:DIRection?
Return Value: <value> (UP or DOWN)
Description:
Identifies the direction (up or down) for executing the list established by LIST:DIR.
Related
Commands: LIST: DIR. (See example, Figure B-3.)
B.36 [SOURce:]LIST:DWELl COMMAND
LIST:DWEL
Syntax:
Short Form: LIST:DWEL <value> (0.0005 to 10),<value>,<value>, . . . to maximum of 1002 values
Long Form: LIST:DWELl <value> (0.0005 to 10),<value>,<value>, . . . to maximum of 1002 values
Description:
Determines how long the main channel parameters will be active.
Sets time value (from 0.0005 to
10) in seconds for List:Dwell locations illustrated in Table B-2. These locations are associated with the
corresponding main channel locations illustrated in Table B-2. The main channel is determined by
FUNC:MODE, either current (FUNC:MODE CURR) or voltage (FUNC:MODE VOLT) If LIST:DWEL is
entered for only location 0, that time duration will apply to all steps when either VOLT:MODE LIST or
CURR:MODE LIST is executed. Related Commands: VOLT:MODE, FUNC:MODE, LIST:CURR,
LIST:VOLT, LIST:DWEL?, LIST:SEQ. (See example, Figures B-2 and B-3.)
B.37 [SOURce:]LIST:DWELl? QUERY
LIST:DWEL?
Syntax:
Short Form: LIST:DWEL?
Long Form: LIST:DWELl?
Return Value: <value>
Description:
Identifies the dwell times entered for the list.
Starting at location established by LIST:QUERy,
returns comma-separated list of up to 16 values indicating the dwell time parameters entered. i.e., the
contents of LIST:DWEL locations of Table B-2. Related Commands: LIST: DWEL, LIST:QUERy. (See
example, Figure B-3.)
B.38 [SOURce:]LIST:DWELl:POINts? QUERY
LIST:DWEL:POIN?
Syntax:
Short Form: LIST:DWEL:POIN?
Long Form: LIST:DWELl:POINts?
Return Value: <value> (0 to 1001)
Description:
Identifies the number of locations for which time values have been entered and the next loca-
tion to be filled by a LIST:DWEL command.
If LIST:DWEL:POIN? returns 6, dwell times have been
entered for locations 0 through 5 and location 6 is the next to be filled by a LIST:DWEL command.
LIST:DWEL, LIST:DWEL:POIN. (See example, Figure B-3.)