4.6 Depth and current intensity of the utilities
WARNING!
The errors of depth measurements may be caused by the magnetic
field distortion produced by adjacent utilities or metal objects,
bends or branches, or in high-noise areas. Always observe the
rules of operation of the Tracer before operation to ensure against
errors.
The utility line depth and current strength are not displayed on the
«RADIO» and «AIR» frequencies. The error of depth is not rated
on the «50Hz» frequency.
Using the above techniques, keep the Tracer over the target utility
axis, as shown in Figure 9. The arrows on the Tracer body and
antenna plain shall be perpendicular to the utility line axis.
Figure 9
– Direct location of the utility depth
The Tracer displays the depth and current of target line by default.
You may switch this function off, and display these data by pressing
the «
» button.
CAUTION!
The depth is measured from the lower surface of the Tracer to the
center of the utility line.
The line depth value is measured from the lower surface of the
antenna to the center of utility.