![Kenyon Lite-Touch Portrait B40547 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/kenyon/lite-touch-portrait-b40547/lite-touch-portrait-b40547_installation-manual-and-operation-manual_1956191009.webp)
SteP #5
Electrical Connection
Before proceeding further, verify that the power supply is disconnected. Verify that the appropriate
electrical supply requirements have been met. Please refer to the table on
page 3
for appropriate
electrical requirements. The cooktop is supplied with a sheathed harness for a connection to an accessible
junction box. The harness consists of three insulated wires. There are two insulated hot lead conductors
(both tinned copper) and one insulated ground conductor (green insulated-tinned copper).
Attach conductor wires to mains in accordance with national, state and local electric codes.
STEP #6
Final Preparations Prior to Use
Remove the plastic film from the cooktop. Clean the cooktop before you use it for the first time.
A thorough cleaning with a recommended cooktop cleaner (
Cerama
Brite
Ceramic Cooktop Cleaner)
will provide a clean, shiny coating on the cooktop surface.
6
!
WARNING- GROUNDING
the entire appliance must be grounded at all times when the
electrical power supply is on. Do not ground the appliance
with the neutral house supply wire (white). A separate ground
must be used.