Final Unit (X45-373X-XX)
Connector Terminal Terminal I/O
Terminal function
No.
No.
Name
CN1
DRV
I
TX driver input signal (Coaxial)
CN3
1
TMP
O
High temperature detector signal
output for fan action
To X57
2
BUP
O
Main DC/BACKUP status output
(A/2)
3
PDT
O
RF power down signal output
TX-RX
4
FAS
I
Fan control signal input
unit
5
PC
I
TX power control signal input
6
8T
I
8V input during transmission
7
NC
–
Reserved
8
GND
–
Ground
CN4
FAB
O
Power supply output for cooling fan
FAG
O
Fan ground
CN5
1
E
–
Ground
2
B
O
Power supply output
3
B
O
Power supply output
CN6
1
Main DC
I
Power supply input (from Main DC
terminal)
CN7
1
BACKUP
I
Power supply input (from BACKUP
terminal)
CN8
1
GND
–
Ground
Display Unit (X54-3330-21) (A/2)
Connector Terminal Terminal I/O
Terminal function
No.
No.
Name
CN501
1
HK
I
Hook detection input/RXD input
2
MIC
I
MIC signal input
To X54
3
MIG
–
MIC ground
(B/2)
4
PTT
I/O PTT input/TXD output
display
5
GND
–
Ground
unit
6
NC
–
No connection
7
SB
O
Power supply output after power switch
8
NC
–
No connection
9
GND
–
Ground
10
5M
O
Common 5V output
11
VLI
I
Volume control input for AF signal
CN502
1
MIG
–
MIC ground
2
MIC
O
MIC signal output
To X57
3
VLI
O
Volume control output for AF signal
(B/2)
4
5C
I
Common 5V input
TX-RX
5
K4
I
KEY input 4
unit
6
K5
I
KEY input 5
control
7
K2
O
KEY output 2
section
8
K3
O
KEY output 3
9
K1
O
KEY output 1
10
HK/RXD
O
Hook detection output/RXD output
11
SOE
I
Output enable for shift register
12
PTT/TXD I/O PTT output/TXD input
Connector Terminal Terminal I/O
Terminal function
No.
No.
Name
13
STB1
I
Strobe data for shift register
14
CLK
I
Clock data input
15
DAT
I
Serial data input
16
PSW
O
Power switch output
17
GND
–
Ground
18
NC
–
No connection
19
SB
I
Power supply input after power switch
20
SB
I
Power supply input after power switch
Display Unit (X54-3330-21) (B/2)
Connector Terminal Terminal I/O
Terminal function
No.
No.
Name
CN601
1
VLI
O
Volume control output for AF signal
2
5M
I
Common 5V input
To X54
3
GND
–
Ground
(A/2)
4
NC
–
No connection
display
5
SB
I
Power supply input after power switch
unit
6
NC
–
No connection
7
GND
–
Ground
8
PTT
I/O PTT output/TXD input
9
MIG
–
MIC ground
10
MIC
O
MIC signal output
11
HK
O
Hook detection output/RXD output
J601
1
NC
–
No connection
(Mic jack)
2
SB
O
Power supply output after power switch
3
GND
–
Ground
4
PTT/TXD I/O PTT input/TXD output
5
MIG
–
MIC ground
6
MIC
I
MIC signal input
7
HK/RXD
I
Hook detection input/RXD input
8
NC
–
No connection
TX-RX Unit (X57-695X-XX) (A/2) : TX-RX Section
Connector Terminal Terminal I/O
Terminal function
No.
No.
Name
CN1
–
–
O
Use for RX helical BPF tuning (Coaxial)
CN2
–
–
I
Use for RX MCF tuning
CN3
–
–
O
Use for RX frequency adjustment
(Coaxial)
CN4
–
–
O
Use for RX MCF tuning
CN14
1
NC
–
No connection
2
DET
O
Detection signal output
To X57
3
NC
–
No connection
(B/2)
4
GND
–
Ground
control
5
ASQ
O
Squelch signal output
section
6
RSSI
O
RSSI signal output
of TX-RX
7
SC
O
Squelch control signal output
unit
8
DP
I
Data input for PLL
9
CP
I
Clock input for PLL
TERMINAL FUNCTION