TK-8180H/8182H
62
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
11. Max DEV
1) Adj item : [DEV_ _]
Power meter Rear
ANT
Front
[ ],[ ] 2.10kHz
±
0.10kHz
adjust
Adjust : [
✳✳✳
.]
panel
panel
(According to the
AG : 1kHz/50mV at MIC terminal
, –)
Deviation meter filter
Deviation
Front
Modular
LPF : 15kHz
meter
panel
MIC jack
HPF : OFF
Oscilloscope
• Narrow
2) Adj item : [D.EV_ _]
→
AG
[D.E.V._ _]
→
[D.E.V._._.]
AF VTVM
Adjust : [
✳✳✳
.]
PTT : ON
• Wide
3) Adj item : [DEV_ _]
4.20kHz
±
0.10kHz
Adjust : [
✳✳✳
]
(According to the
PTT : ON
, –)
12. MIC
[Panel test mode]
Check
2.5~3.5kHz
sensitivity
1) CH-Sig : 1-1
check
AG : 1kHz/5mV at MIC terminal
(Wide only)
PTT : ON
13. QT deviation 1) Adj item : [QT_ _ _]
Front
[ ],[ ] 0.35kHz
±
0.05kHz
adjust
Adjust : [
✳✳✳
.]
panel
Deviation meter filter
LPF : 3kHz
HPF : OFF
• Narrow
2) Adj item : [Q.T_ _ _]
→
[Q.T._._ _]
→
[Q.T._._._.]
Adjust : [
✳✳✳
.]
PTT : ON
• Wide
3) Adj item : [QT_ _ _]
0.75kHz
±
0.10kHz
Adjust : [
✳✳✳
]
PTT : ON
14. DQT
1) Adj item : [DQT_ _]
0.35kHz
±
0.05kHz
deviation
Adjust : [
✳✳✳
.]
adjust
Deviation meter filter
LPF : 3kHz
HPF : OFF
• Narrow
2) Adj item : [D.QT_ _]
→
[D.Q.T._ _]
→
[D.Q.T._._.]
Adjust : [
✳✳✳
.]
PTT : ON
• Wide
3) Adj item : [DQT_ _]
0.75kHz
±
0.10kHz
Adjust : [
✳✳✳
]
PTT : ON
15. LTR
1) Adj item : [LTR_ _]
0.75kHz
±
0.10kHz
deviation
Adjust : [
✳✳✳
.]
adjust
Deviation meter filter
LPF : 3kHz
HPF : OFF
• Narrow
2) Adj item : [L.TR_ _]
→
[L.T.R._ _]
→
[L.T.R._._.]
Adjust : [
✳✳✳
.]
PTT : ON
• Wide
3) Adj item : [LTR_ _]
1.00kHz
±
0.10kHz
Adjust : [
✳✳✳
]
PTT : ON
ADJUSTMENT (TK-8182H)