ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-5400
7. MIC
1) Set panel tuning mode.
Deviation
Panel
ANT
Panel
Top 1/
Fixed digit number
sensitivity
CH : 4 (Center)
meter
Top 2
129.
adjustment
LCD display : MIC LO
Oscilloscope
PTT : ON
Set at constant value 129.
AG
Side
Universal
Press [Side 2] to store the
AF VTVM
digit number after adjustment.
8. VCO/VCXO
1) Set panel tuning mode.
Make the demodula- Remember to set
balance
CH : 4 (Center)
tion waveform into
oscilloscope’s coupling to DC.
adjustment
LCD display : BAL LO
square shape.
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
De-emphasis : OFF
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
9. VCO/VCXO
1) Set panel tuning mode.
balance
CH : 4 (Center)
adjustment
LCD display : BAL t LO
(TA)
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
10. APCO high
1) Set panel tuning mode.
Deviation
Panel
ANT
2827Hz
2771~2883Hz
deviation
CH : 4 (Center)
meter
adjustment
LCD display : HDVA LO
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
De-emphasis : OFF
DET : Peak (+/–)
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
11. APCO high
1) Set panel tuning mode,
deviation
then press [Orange] key to
adjustment
enter the 3 point adjustment
at low
mode.
frequency
LCD display : HDVA L LO
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
12. APCO high
1) Set panel tuning mode.
deviation
and press [Side 2] key to set
adjustment
high frequency.
at high
LCD display : HDVA H LO
frequency
PTT : ON
Press [Side 2] to store the
digit number after adjustment.