TK-3140
29
Common Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remark
1. Setting
1) BATT terminal voltage:7.5V
2) SSG Standard modulation
[Wide] MOD:1kHz, DEV:3kHz
[Narrow] MOD:1kHz, DEV:1.5kHz
2. VCO lock
[Panel Test Mode]
voltage
1) CH-Sig:2-1
Power meter
Panel
ANT
TX-RX
TC2
4.1V
±
0.1V
RX
2) CH-Sig:3-1
DVM
TX-RX
CV
Check
0.6V or more
TX
3) CH-Sig:2-1
TC1
4.1V
±
0.1V
PTT:ON
4) CH-Sig:3-1
Check
0.6V or more
PTT:ON
Transmitter Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remark
ADJUSTMENT
1. Frequency
1) Adj item [FREQ]
Power meter
Panel
ANT
Panel
Encoder
Center frequency
±
100Hz
Adjust
Adjust [
∗∗∗
]
Am meter
knob
PTT:ON
2. Hight Power 1) Adj item [HPOW]
Encoder
4.0W
±
0.1W
Adjust
Adjust [
∗∗∗
]
knob
2.0A or less
2) Adj item
[L HPOW]
➞
[L2 HPOW]
➞
[C HPOW]
➞
[H2 HPOW]
➞
[H HPOW]
Adjust [
∗∗∗
]
PTT:ON
3. Hight Power [Panel Test Mode]
Check
1) CH-Sig:1-1
Check
3.7~4.3W
PTT:ON
2.0A or less
2) CH-Sig:2-1
PTT:ON
3) CH-Sig:3-1
PTT:ON
4. Low Power 1) Adj item [LPOW]
Panel
Encoder
1.0W
±
0.05W
Adjust
Adjust [
∗∗∗
]
knob
1.0A or less
2) Adj item
[L LPOW]
➞
[L2 LPOW]
➞
[C LPOW]
➞
[H2 LPOW]
➞
[H LPOW]
Adjust [
∗∗∗
]
PTT:ON
5. Low Power [Panel Test Mode]
Check
1) CH-Sig:1-1
Check
0.5~1.5W
Set low power (Push [B])
1.2A or less
PTT:ON
2) CH-Sig:2-1
PTT:ON
3) CH-Sig:3-1
PTT:ON