TK-2317
32
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
6. DQT
Deviation
[Wide]
1) TEST CH: 1
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
PTT:
ON
Power
meter
Deviation
meter
Oscilloscope
ANT
FPU
0.75kHz
±40Hz
7. QT
Deviation
[Wide]
1) TEST CH: 1
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
PTT:
ON
0.75kHz
±40Hz
8. DTMF
Deviation
[Wide]
1) TEST CH: 1
Deviation meter fi lter
LPF: 15kHz
HPF: OFF
PTT:
ON
3.0kHz
±100Hz
9. MSK
Deviation
[Wide]
1) TEST CH: 1
Deviation meter fi lter
LPF: 15kHz
HPF: OFF
PTT:
ON
3.0kHz
±100Hz
Note: Regarding deviation alignment item, narrow value is calculated from wide alignment value.
Receiver Section
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. Sensitivity
(Semiauto-
matic)
1) TEST CH: Low, Center, High
(3 points)
SSG otuput : –90dBm
(7.08µV)
SSG MOD: 3.0kHz
SSG
DVM
Oscilloscope
ANT
FPU
Press [Start]
(Auto tuning)