![Kenwood TK-2302VK Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/kenwood/tk-2302vk/tk-2302vk_product-brochure_191477002.webp)
All accessories and options may not be available in all markets.
Contact an authorized Kenwood dealer for details and complete list of all accessories and options.
Model
TK-2302VK
TK-3302UK
GENERAL
Frequency Range
Type 1
136-174 MHz
450-490 MHz
Number of Channels
16
Channel Spacing
Wide/Narrow
25 kHz/12.5 kHz
Operating Voltage
7.5V DC±20%
Battery Life (5-5-90 during hi-power battery saver: OFF/ON)
with KNB-45L (2000mAh)
Approx. 12 hours / 18 hours
Operating Temperature Range
-22°F ~ +140°F (-30°C ~ +60°C)
Frequency Stability
±2.5 ppm (-30°C ~ +60°C)
Antenna Impedance
50
Ω
Dimensions (W x H x D), Projections not included
with KNB-45L
2.13” x 4.8” x 1.33” (54 x 122 x 33.8 mm)
Weight (Net)
Radio Only
5.6oz (160g)
with KNB-45L
9.9oz (280g)
FCC ID
Type 1
ALH413500
ALH413600
Model
TK-2302VK
TK-3302UK
RECEIVER
(Measurements made per TIA/EIA-603)
Sensitivity (12dB SINAD)
Wide
0.25 µV
Narrow
0.28 µV
Selectivity
Wide
70 dB
Narrow
60 dB
Intermodulation Distortion
Wide
65 dB
Narrow
60 dB
Spurious Response
65 dB
60 dB
Audio Output (8
Ω
Impedance)
500mW with less than 10% distortion
TRANSMITTER (Measurements made per TIA/EIA-603)
RF Power Output
High
5 W
4 W
Low
1 W
1 W
Spurious Response
65 dB
Type of Emission
Wide
16KØF3E
Narrow
11KØF3E
FM Noise (EIA)
Wide
45 dB
Narrow
40 dB
Audio Distortion
Less than 5%
Kenwood follows a policy of continuous advancement in development.
For this reason specifications may be changed without notice.
FleetSync
®
is a registered trademark of Kenwood Corporation.
Windows
®
is a registered trademark of Microsoft Corporation in the United States and other countries.
Options
Specifications
■
KNB-45L
Li-Ion Battery Pack
(2000 mAh)
■
KSC-35K
Fast Charger (3-Hour)
■
KRA-16
VHF Stubby Antenna
■
KRA-17
UHF Stubby Antenna
■
KRA-22
VHF Low Profile
Helical Antenna
■
KRA-23
UHF Low Profile
Helical Antenna
■
KRA-26
VHF Helical Antenna
■
KRA-27
UHF Whip Antenna
■
KMC-45
Speaker Microphone
■
KMC-21
Compact Speaker
Microphone
■
KEP-2
Earphone Kit
(2.5mm plug)
■
KHS-7
Single-Muff Headset
■
KHS-7A
Single-Muff Headset
with In-line PTT
■
KHS-8BL/BE
2-wire Palm Mic with
Earphone (Black/Beige)
■
KHS-9BL/BE
3-wire Lapel Mic
with Earphone (Black/Beige)
■
KHS-22
Behind-the-head
Headset with PTT
■
KHS-23
2-wire Palm Mic
■
KHS-25
D-Ring Ear Hanger
with PTT & Boom Mic
■
KHS-26
Earbud In-line
PTT Headset
■
KHS-27
D-Ring In-line
PTT Headset
■
KMB-25
Six Unit Charger
Adapter
■
KMB-28
Six Unit Charger
Adapter for six
KSC-35K chargers
■
KBH-10
Belt Clip
■
KWR-1
Water Resistance Bag
■
KLH-126
Nylon Case
(chargers not included)
(chargers not included)
*To meet IP54/55, the 2-pin connector cover has to be connected on the radio or the locking bracket has to be attached to the KMC-45 external speaker microphone.
ADS#33808 Printed in USA
JQA-QMA1205
Applicable MIL-STD & IP
Footnotes from front:
1
DTMF Encode: PTT ID, Auto-Dial (8 numbers); DTMF Decode:
Group Codes (A, B, C, D, # and *) and Radio Stun.
2
KPG-119D required: Windows
®
98/ 2000/ Me/XP/Vista compatible.
3
ID List capacity: 8 ID's.
Standard
MIL 810C
MIL 810D
MIL 810E
MIL 810F
Methods/Procedures
Methods/Procedures Methods/Procedures Methods/Procedures
Low Pressure
500.1/Procedure I
500.2/Procedure I, II
500.3/Procedure I, II
500.4/Procedure I, II
High Temperature
501.1/Procedure I, II
501.2/Procedure I, II
501.3/Procedure I, II
501.4/Procedure I, II
Low Temperature
502.1/Procedure I
502.2/Procedure I, II
502.3/Procedure I, II
502.4/Procedure I, II
Temperature Shock
503.1/Procedure I
503.2/Procedure I
503.3/Procedure I
503.4/Procedure I, II
Solar Radiation
505.1/Procedure I
505.2/Procedure I
505.3/Procedure I
505.4/Procedure I
Rain
506.1/Procedure I, II
506.2/Procedure I, II
506.3/Procedure I, II
506.4/Procedure I, III
Humidity
507.1/Procedure I, II
507.2/Procedure II, III
507.3/Procedure II, III
507.4
Salt Fog
509.1/Procedure I
509.2/Procedure I
509.3/Procedure I
509.4
Dust
510.1/Procedure I
510.2/Procedure I
510.3/Procedure I
510.4/Procedure I, III
Vibration
514.2/Procedure VIII, X
514.3/Procedure I
514.4/Procedure I
514.5/Procedure I
Shock
516.2/Procedure I, II, V
516.3/Procedure I, IV
516.4/Procedure I, IV
516.5/Procedure I, IV
International Protection Standard
Dust & Water Protection
IP54/55