TK-2207
36
ADJUSTMENT /
调整
1.Frequency
1) CH:High
Frequency counter ANT
VR1
173.900 MHz
±50Hz
Adjust
2) PTT:ON
2.High power TEST CH: Low
Power meter
Programming
5.0W ±0.1W
Adjust
Low’
Ammeter
Software:KPG-87D
1.9 A or less
Center
High’
High
(5 points)
BATT terminal voltage:7.5V
PTT:ON
3.Low power
TEST CH: Low
1.0W ±0.1W
Adjust
Low’
0.9 A or less
Center
High’
High
(5 points)
BATT terminal voltage:7.5V
PTT:ON
4.Max deviation TEST CH: Center
Power meter
ANT
4.2kHz
±50Hz
Adjust
Low
Deviation meter
SP/MIC connector
(According to
[Wide]
High
Oscilloscope
the lager +,–)
(3 points)
AG
AG:1kHz/150mV
AF VTVM
Deviation meter filter
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
2.2kHz
±50Hz
PTT:ON
(According to
the lager +,–)
5.VOX 1
TEST CH:Center
Writing
AG:1KHz/45mV
Common Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
1.Setting
1) BATT terminal votage:7.5V
2) SSG standard modulation
[Wide] MOD:1kHz,DEV:3kHz
[Narrow] MOD:1kHz,DEV:1.5kHz
2.VCO lock
1) CH:High
Power meter
ANT
TC2
4.0V
±0.1V
voltage
DVM
CV
RX
2) CH:Low
Check
0.6V or more
3.VCO lock
3) CH:High
TC1
4.2V
±0.1V
voltage
PTT:ON
TX
4) CH:Low
Check
0.6V or more
PTT:ON
Transmitter Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark