25
Repair Jig (Chassis)
Use jig (part No.: A10-4060-04) for repairing the TK-2140.
Place to TX-RX unit on the jig and fit it with screws.
The jig facilitates the voltage check and protects the final
amplifier FET when the voltage on the flow side of the TX-RX
unit is checked during repairs.
How to Remove the Cable
1. Gently draw out both sides of the connector lever uniformly
in the direction of the arrow with tweezers.
(CN303, CN304, CN305, CN306)
Tweezers
Flat cable
Lever
Regular screwdriver
2. Gently rise up the connector lever in the direction of the
arrow with a fine regular screwdriver or tweezers.
(CN301, CN302, CN400)
■
How to assemble the antenna connector and its
terminal.
The antenna connector and its terminal are supplied as
separate parts.
When replacing the antenna connector and/ or terminal,
assemble the parts prior to the replacement.
1. Mount the antenna connector onto the chassis
➀
.
•
Double-sided adhesive tape is attached to the terminal; peel
off the tape cover
➁
.
•
Attach the terminal to the antenna connector as shown
below.
•
Slide the antenna terminal along the adhesive cushion on
the chassis so that the adhesive part on the terminal is firmly
attached to the antenna connector
➂
.
2. Remove the antenna connector from the chassis with its
terminal attached, then solder the center part of antenna
connector to its terminal
√
.
Do not use excessive solder on terminal.
1
2
TOP
Bottom
cushion
3
4
ADJUSTMENT