A
C
E
B
D
2
1
3
5
7
4
6
SW-38HT
SUB-IN
JK1
D2
(1/2)
IC1
D1
(2/2)
IC1
(2/2)
IC2
(1/2)
IC2
CN1
CN2
(1/2)
D3
D4
IC3
(2/2)
IC3
Q1
D6
D7
Q4
Q3
Q2
D5
Q6
Q5
CN3
D8
D10
D9
D11
Q10
Q11
Q12
Q9
Q8
Q7
D12
CN6
D14
D13
D17
D16
CN5
D15
SW1
POWER SW
CN4
CN10
CN7
USED
(K) (P) (E) (X) TYPE
CN9
S1
USED (Y) TYPE
IC1-3 : TL072
IC4
: TDA7293V
Q1,3,4,6,8,9,11
: 2N3906
Q2,7 : 2N3904
Q5
P1
P2
L1
22K
R2
22u25
+
C2
100P
C4
8
2
4
3
1
C3 1000P
R3 47K
6
5
7
1K
R4
10K(B)
VR1
10u50
+
C5
5
6
7
2
3
1
4
8
22K
R7
0.033
C9
22K
R8
0.068
C8
∗
C6
∗
C7
R5 10K
∗
R6
10u50
+
C10
1
2
3
4
1
2
3
4
47u25
C1
1
+
47u25
C12
+
8
2
4
3
1
R18
R19
10K
R21
1K
R20
2.2K
R15
10K
R23
R17
5
6
7
4.7u50
C19
100K
R16
10K
+
22K
390
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
C15
47u50
390
R13
C16
1
R14
3.9 2W
22K
R12
1K
R10
47u50
C14
+
9
10
1K
R9
R52
R32
R31
10u50
C21
1K
R30
47u25
C20
+
4.7K
R28
10K
R29
100K
22K
+
10K
R25 47K
R26 47K
10K
R27
68
R33
1
2
RL1
22K
R37
C23
10u50
100K
R38
33K
R34
22K
R35
C22
10u50
4.7K
R36
22K
R41
22K
R42
R40
R39
R44
22K
R43
10u50
C24
+
2.2K
R49
47u25
C26
+
2.2K
R48
+
R51
+
R50
1/4W
1/4W
470
R47
2W
2W
470
R46
47u25
C28
9.1K
47u25
C27
10K
22K
22K
+
C25
1u50
47K
9
10
1
2
3300u50
C30
3300u50
C29
++
6.8K
R45
3
1
2
0.047
C32
0.047
C31
2
1
1
2
(K,P) : AC120V 60Hz
50/60Hz
: AC110-120V/220-240V~
: AC230V~ 50Hz
: AC100V~ 50/60Hz
(J)
(E)
(Y)
5
6
4
3
2
1
8
10
9
7
2
1
3
4
5
∗
F1
BLK
WHT
0.01
C33
T1
1
3
2
1
2
3
4
T1.25AL 250V
220-240V
110-120V
T2
∗
JW 0
: AC240V~ 50Hz
(X)
F2
T2AL
T2A
T1.25AL
T2.5A
F1
T1.25AL
AUSTRALIA
EUROPE
JAPAN
E
X
J
DESTINATION
COUNTRY
U.S.A.
CANADA
PX
ABB.
Y
P
K
NO
YES
NO
NO
NO
JW 0
39K
R1
1/4W
22K
R1
1
47K
R24
C17
0.047
C18
0.047
C13
47P
B
+B
B
+B
+B
B
B
+B
+B
B
+B
B
+B
B
B
+B
+B
B
+B
B
+B
IC4
I/O
MAIN
LED
SW-38HT
POWER SUPPLY
C6,7
0.068
0.68
R6
270K
18K
CAUTION:
For continued safety, replace safety critical components only with
manufacturer's recommended parts (refer to parts list).
indicates safety crit-
ical components. For continued protection against risk of fire, replace only
with same type and rating fuse(s). To reduce the risk of electric shock, leak-
age-current or resistance measurements shall be carried out (exposed parts
are acceptably insulated from the supply circuit) before the appliance is
returned to the customer.
The DC voltage is an actual reading measured
with a high impedance type voltmeter with no
signal input. The measurement value may vary
depending on the measuring instruments used
or on the product.
4
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299