![Kenwood RXD-V313 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/kenwood/rxd-v313/rxd-v313_service-manual_192924008.webp)
RXD-V313
8
ADJUSTMENT
FM 75
Ω
AM
ANTENNA
GND
(A)
(C)
(D)
AM-SG
FM-MPX-SG
FM-MPX-SG
POLAR SG
Dummy antenna
Oscilloscope
AC voltmeter
(B)
Distortion meter
TO TUNER UNIT
CN101, pin 9 (Lch)
pin 7 (Rch)
pin 8 (GND)
N O .
I T E M
INPUT
SETTING
OUTPUT
S E T T I N G
TUNER
S E T T I N G
ALIGNMENT
P O I N T S
ALIGN FOR
F I G .
1.
IF
(A)
98 MHz,1 kHz MOD
±75 KHz (DEV)
60 dBu (ANT INPUT)
(B)
98MHz
T101
Maximum output
(Minimum distortion)
2
.
LOW END
TRACKING
(A)
87MHz, 1 kHz MOD
±75 kHz (DEV)
35 dBu ( ANT INPUT)
(B)
87MHz
L102
Maximum output
3
.
HI END
TRACKING
(A)
108MHz,1 kHz MOD
±75 kHz (DEV)
35 dBu (ANT INPUT)
(B)
108MHz
TC101
Maximum output
4.
VT
–
Connect the DC
voltage meter to
TP2.
87.5 MHz
L103
VT=1.0V±0.05V
108 MHz
–
Check the
VT=7.0V±1.0V
N O .
I T E M
INPUT
SETTING
OUTPUT
S E T T I N G
TUNER
S E T T I N G
ALIGNMENT
P O I N T S
ALIGN FOR
F I G .
1.
IF
(D)
531 kHz 1 kHz,
30% MOD
60 dBu (ANT INPUT)
(B)
531 kHz
T102
Maximum output
(Minimum distortion)
2.
LOW END
TRACKING
(D)
531 kHz 1 kHz,
30% MOD
30 dBu (ANT INPUT)
(B)
531 kHz
L104
Maximum output
3.
HIGH END
TRACKING
(D)
1602 kHz 1 kHz,
30% MOD
30 dBu (ANT INPUT)
(B)
1602 kHz
TC102
Maximum output
4.
VT
–
Connect the DC
voltage meter to
TP2.
531 kHz
L105
VT=1.2V±0.05V
1602 kHz
–
Check the
VT=7.3V±1.0V
FM SECTION
MW SECTION
INSTRUMENTS CONNECTION
RXD-V313(K)
COVER1,1(
98.12.11
9:46
y [ W 15