RXD-M52
7
CD section
NO.
ITEM
INPUT
SETTINGS
OUTPUT
SETTINGS
CD PLAYER
SETTINGS
ALIGNMENT
ALIGN FOR
FIG.
TEST MODE : While pressing the CD PLAY/PAUSE key, plug the power cord into the AC power wall output.
Load the TEST DISC.
[1]
LASER CURRENT
CHECK
Test disc
type 4
Connect the DC voltmeter
between
3
and
4
of CN4
on X29.
Press the PLAY/PAUSE
key to check that the
display is 03 or05.
—
50
±
20mA
[2]
FOCUS ERROR
BIAS
(Set up vertically)
Test disc
type 4
Connect an oscilloscope
as follows.
Press the PLAY/PAUSE
key . Confirm that the
display is 05.
FE BIAS
VR 1
(V/H version only)
Optimum eye pattern
[3]
FOCUS ERROR
BIAS
(Set up horizontally)
Test disc
type 4
Connect an oscilloscope
as follows.
CH1:RF(X29,CN4,
1
)
GND:VC(X29,CN4,
2
)
CH1:RF(X29,CN4,
1
)
GND:VC(X29,CN4,
2
)
Press the PLAY/PAUSE
key . Confirm that the
display is 05.
FE BIAS
VR 2
Optimum eye pattern
Note:
Type 4disc: SONY YEDS-18 Test Disc or equivalent.
Keep the step of adjustment.
-
-
CASSETTE DECK
NO.
ITEM
INPUT
SETTINGS
OUTPUT
SETTINGS
CASSETTE DECK
SETTINGS
ALIGNMENT
ALIGN FOR
FIG.
Unless otherwise specified, set the respective switches as follows:
TAPE: NORMAL INPUT: AUX IN OUTPUT: AUX OUT
0dBm=0.775V
ø
. Cassette mechanism (REC/PB head adjustment)
Demagnetization
and cleaning
—
—
(POWER OFF)
demagnetization
(PLAY)
cleaning
REC/PB head
erase head
capstan
pinch roller
Demagnetize the REC/PB head by
head eraser. Clean the REC/PB head
,eraser head, capstan and pinch
roller with a cotton swab immersed
in alcohol.
REC/PB head
azimuth
TCC-153
MTT-114
10kHz,-10dB
(B)
PLAY
Adjust the output to maximum and
adjust the azimuth adjustment
screw for the Lissajous waveform
pattern of the oscilloscope to
become close to a 45ß straight line.
¿
. Capstan motor adjustment
Tape speed
(NORMAL)
TCC-110
MTT-111
3kHz
(B)
PLAY
VR.
inside motor
Adjust so that the frequency 3kHz
at the center of the tape.
¡
(B)
PLAY
VR1(Lch),VR2(Rch)
-2.5dBm
(B)
REC
PLAY
(A)
VR3(Lch)
VR4(Rch)
-24dBm
Measurement equipment connection
FWD
RVS
{
(A)
(B)
AC voltmeter
AC voltmeter
Oscilloscope
Distortion meter
AG
ADJUSTMENT