RD-M23
8
Check the PWB pattern between emiter of Q607 and emiter of
Q861.
• Laser failure.
Is 0V applied to the pin 57 (SEL) of IC802 ?
Yes
No
Does the laser come on when pattern cut between pin 8 (SEL) of
IC801 and pin 57 (SEL) of IC802 ?
Check the PWB pattern between IC701 and IC802 (BUCK/CCE/
BUS0~3)
Yes
Yes
No
Check the peripheral parts of IC801 and Q801. If it is normal, the
optical pickup is faulty.
No
Check CNP802/CNW3. If it is normal, the optical pickup is
faulty.
Is approx. 2V applied to the collector of Q801.
• Focus failure.
Does the optical pickup move up and down when the disc is
removed?
Is the following waveform ouput at the pin 43 (FEI) of IC802
when the disc is set?
Is the waveform shown above input at the pin 44 (SBAD) of
IC802?
Yes
Yes
No
No
The optical pickup is faulty.
Check as stated in item "FOCUS SERVO SAWTOOTH WAVE
FAILURE".
Yes
Check the periphery of IC801 and CNP802/CNW3. Is it normal?
No
Check the pattern between pin 13 of IC801 and pin 44 of IC802.
Check the periphery of IC801 and CNP802/CNW3.
IC801 is faulty.
Yes
Is +6.2V applied to the emiter of Q861 ?
Is +5V applied to the collector of Q861 ?
Yes
No
No
Check the peripheral parts of IC804 and Q861.
Is +5V applied to the pin 62 (VDD) of IC802 ?
Is +5V applied to the pin 1 (VCC) of IC801 ?
Yes
No
No
Check the PWB pattern between collector of Q861 and pin 62 of
IC802.
Check the PWB pattern between collector of Q861 and pin 1 of
IC801.
pin 43
(FEI)
pin 48
(FOO)
pin 44
(SBAD)
Yes
Yes
• Focus servo sawtooth wave failure.
Is +6.2V applied to the pins 21 and 22 (VCC) of IC804 ?
Is sawtooh wave output to the pin 48 (FOO) of IC802 ?
IC802 is faulty.
No
Yes
Yes
Is sawtooth wave obtained between pins 26 and 27 of IC804 ?
No
No
Check the PWB pattern
between pin 7 of IC804
and pin 60 (CD STB) of
IC701.
Is +5V applied to the pin 7
(MUTE) of IC804 ?
Check the PWB pattern between pin 48 (FOO) of IC802 and pins
24 and 25 of IC804. If OK. IC804 is faulty.
Check the PWB pattern between pin emiter of Q607 and IC804.
No
Is sawtooth wave obtained between pins 13 and 16 of
CNP802/CNW3 ? (as shown above)
Yes
Check the PWB pattern between CNP802/CNW3 and IC804.
No
CNP802/CNW3 connection failure or optical pickup failure.
Yes
• Spindle motor clv servo failure.
Is above wave obtained between pins 11 and 12 of IC804 ?
Is following wave output to the pin 55 (DMO) of IC802 when
the CD TEST MODE "STEP 3" is changed to " STEP 4" ?
No
Yes
Check the procedure in "HF ERROR".
If OK. IC802 is faulty.
Check the PWB pattern between pin 55 (DMO) of IC802 and pins
9 and 10 of IC804. If OK. IC804 is faulty.
No
Is above wave obtained between pins 9 and 12 of CNP802/
CNW3 ?
Yes
Check the PWB pattern between CNP802/CNW3 and IC804.
No
CNP802/CNW3 connection failure or optical pickup failure.
Yes
DMO
Yes
1.5~2.5sec
1.5~2.5sec
TROUBLE SHOOTING