R-SE9/SE9T
7
ADJUSTMENT
NO.
ITEM
INPUT
SETTINGS
OUTPUT
SETTINGS
TUNER
SETTINGS
ALIGNMENT
POINTS
ALIGN FOR
FIG.
1
DISCRIMINATOR
(A)
98.0kHz
1kHz, ±75kHz dev.
60dBµ(ANT input)
Connect a DC
voltmeter
between
Pin 1 and Pin 2
of CN 2.
MONO
98.0MHz
L 31
0V
(a)
L 32
Minimum distortion.
2
DISTORTION
(STEREO)
(C)
98.0MHZ
1kHz, ±68.25kHz dev.
Pilot: ±6.75kHz dev.
60dBµ(ANT input)
(B)
AUTO
98.0MHz
IFT (A1)
Minimum distortion.
(a)
NO.
ITEM
INPUT
SETTINGS
OUTPUT
SETTINGS
AMP
SETTINGS
ALIGNMENT
POINTS
ALIGN FOR
FIG.
POWER: ON
1
IDLE CURRENT
—
Connect a DC
voltmeter across
CN9(L)
CN10(R)
(X09, A/4)
Volume : 0
VR1(L)
VR2(R)
(X09, A/4)
18mV
(b)
SYSTEM
CONTROL
ANTENNA
AM
GND
CD
IN
REC
PLAY
SUPER
WOOFER
PRE OUT
SPEAKERS
( 6 - 16 )
R
TAPE
TAPE
REC
PLAY
MD
MD
AUX
FM75
+
-
IN
L
R
R
L
L
Oscilloscope
Distortion meter
AC voltmeter
Dummy antenna
(A)
(B)
(C)
(D)
AG
AG
FM SG
MPX
AG
FM SG
AM SG
(a)
(b)
CN9(L)
CN10(R)
DC voltmeter
18mV
FM SECTION
X05-4622-71 (T TYPE)
AUDIO SECTION (X09-4952-70)
SYSTEM CONNECTIONS
R-SE9/SE9T(K)
1P
98.4.25
14:46
y [ W
14
Содержание R-SE9
Страница 21: ...R SE9 SE9T 25 PARTS DESCRIPTIONS ...