background image

Thank you for purchasing this new DC Power Supply. This unit has been carefully engineered and 

manufactured to rigid quality standards, and should give you satisfactory and dependable operation for many 

years. 

This Instruction Manual covers the following model versions: 

U.S.A. and Canada, 
Europe and Oceania, 
U.K., 
and General Markets 

The following explicit definitions apply in this Instruction Manual. 

WARNING : Risk of fire or electric shock may occur. DO NOT DISREGARD! 
CAUTION : Equipment damage may occur, but not personal injury. 

NOTE : If disregarded, inconvenience only, no risk of equipment damage or personal injury. 

IMPORTANT 

1. Please read this Instruction Manual carefully before placing your DC Power Supply in service. 
2. Save this Instruction Manual. 

NOTE 

The first time this equipment is used, a faint odor may be given off by the power transformer. This is merely 
the filler in the power transformer or the wax on the capacitors evaporating as the unit warms up. This is 

normal and is not a defect. 

For United Kingdom 

Always remove the mains plug from the wall outlet prior to any 

maintenance of this equipment. 

WARNING: THIS EQUIPMENT MUST  B E EARTHED. 

IMPORTANT: 
This plug contains a 13 ampere fuse. Should the fuse need to be 
replaced, ensure that the replacement fuse has a current rating 
of 13 amperes. Use only fuses stamped with an ASTA or BSI 
approval mark on the body of the fuse. 

If the moulded plug is incompatible with the outlets in your home, 
remove the fuse, then cut off and discard the plug. There is danger 
of severe electrical shock should the cut off plug be inserted into 
a live outlet. If a new plug is fitted, observe the wiring code as 
shown below. If in doubt, consult a qualified electrician. 

The wires in the mains lead of this product are coloured in 
accordance with the following code: 

Green and Yellow: Earth 

Blue : Neutral 
Brown : Live 

As wire colours in the mains lead of this equipment may not 
correspond with the coloured markings identifying the terminals 

in your plug, proceed as follows: 

Wire colour Plug terminal marking 

Green and Yellow E or or Green or Green and 

Yellow 

Blue N or Black 
Brown L or Red 

Green and Yellow 
to Earth 

IF IN DOUBT-CONSULT A COMPETENT ELECTRICIAN. 

Brown to 

Live 

Blue to 

Neutral 

Plug-

Содержание PS-33

Страница 1: ... PRINTED IN JAPAN B62 0142 10 K E M P T X MC 93 12 11 10 9 8 7 6 5 4 3 2 DC POWER SUPPLY PS 33 PS 53 INSTRUCTION MANUAL KENWOOD CORPORATION KENWOOD ...

Страница 2: ...m Always remove the mains plug from the wall outlet prior to any maintenance of this equipment WARNING THIS EQUIPMENT MUST BE EARTHED IMPORTANT This plug contains a 13 ampere fuse Should the fuse need to be replaced ensure that the replacement fuse has a current rating of 13 amperes Use only fuses stamped with an ASTA or BSI approval mark on the body of the fuse If the moulded plug is incompatible...

Страница 3: ...ll the power cord when disconnecting it from the AC wall outlet Grasp the plug and ensure that your fingers do not touch the live pins Do not place the unit in areas of excessive dust high humidity or on unstable surfaces To avoid risk of electric shock under no circumstances should the unit be opened If an abnormal odor or smoke is detected immediately turn the power off and pull out the power pl...

Страница 4: ...50 duty cycle 20 5 A max Continuous operation for 1 hour Output voltage regulation Within 0 7 V at 120 220 230 240 VAC 10 variation with 16A Within 0 7 V at load current variation from 2 to 16A Ripple voltage Less than 20 mVrms at 13 8 VDC 16A Power consumption Approx 550 W at 13 8 VDC 22 5A Dimensions WXHXD Dimensions in include projections 173X96X296 mm 173X107X322 mm 6 13 16 X 3 25 32 X11 21 32...

Страница 5: ...ts version CAUTION Make sure that the AC cable is disconnected before selecting an AC voltage When changing an AC operating voltage select the desired voltage with the selector switch located on the side cover In this case the correct fuse must be installed referring to Section 5 4 FUSE REPLACEMENT WARNING Never connect AC power to the DC Power Supply until installation is complete CAUTIONS 1 Befo...

Страница 6: ...set at the factory and should only be readjusted by a qualified technician with proper test equipment Attempting service or adjustment without factory authorization can void the DC Power Supply s warranty If your DC Power Supply fails to work contact the authorized KENWOOD dealer from which you purchased it for quick reliable repair NOTES 1 When claiming warranty service please include a photocopy...

Страница 7: ...CIRCUIT DIAGRAM SCHEMATIC DIAGRAM Q 1 Q 2 2 N 5 8 8 5 D 1 S 2 5 V B 1 0 D2 S L P 1 4 4 B Note Circuit is su t to change without notice due to advancement in technology ...

Страница 8: ...1 Note Circuit is subjec change without notice due to advancement in technology 01 2 S A 5 2 CY 02 0 3 0 5 Z S C 2 4 5 8 CY Q4 2SB941 Q 0 1 5 8 t 1 S 1 5 5 5 02 3 J 0 S A 3 A 1 D 6 UZ9 1BL D7 UZ15BH T H 1 3 2 0 2 7 T H 2 5 T P 1 L ...

Страница 9: ...AC F05 6021 05 6A Europe and General Market 120 VAC F05 6021 05 6A Europe and General Market 230 VAC F05 4024 05 4A U K 240 VAC F05 4024 05 4A Oceania 240 VAC F05 3022 05 3A NOTE Fuse Holder is located on rear panel for U S A version as Fig 4 2 Other version except for U S A version fuse holder is located inside of the top cover 5 5 SUPPLY CORD REPLACEMENT Oceania version only If the supply cord o...

Страница 10: ...KENWOOD ...

Отзывы: