17
QT/ DQT SETTINGS (ANALOG)
Quiet Talk (QT) and Digital Quiet Talk (DQT) are functions that
reject undesired signals on your channel. You will hear a call
only when you receive a signal that contains a matching QT
tone or DQT code. If a call containing a different tone or code
is received, squelch will not open and you will not hear the call.
Likewise, when transmitting using QT or DQT, the receiving
station must have a matching tone or code to hear your call.
Be aware that other parties can still hear your calls if they set
up their transceiver with the same tone or code.
The default QT/DQT settings for each channel are provided in
the table {page 18}.
To change the QT/DQT settings of a channel of Analog:
1
Follow the operating steps in Zone Selection to select the
zone type (analog).
2
Rotate
the
Selector
to select the channel to change.
•
The transceiver announces Channel number.
3
Press
the
Side 1
or
Side 2
key to select the QT/DQT setup.
•
The transceiver announces “QT/DQT” and “Channel”
alternately with each press of the
Side 1
or
Side 2
key.
4
Press and release the
PTT
switch.
•
A beep will sound and the transceiver announces QT/DQT
number.
5
Press
the
Side 1
or
Side 2
key to increment/ decrement the
Tone number, to select the new tone or code.
•
QT/DQT table numbers and their corresponding tones/ codes
are provided in the table
{page 18}
.
•
Press and hold the
Side 1
or
Side 2
key to increment/
decrement the Tone number by 5 at a time.
•
A voice announcement will inform you of the currently selected
Tone number.