Master Operation

The PAR Series power supplies are compatible with single-control
operation when they are incorporated in a system, with one master
capable of controlling up to ten slave power supplies, controlling
all the functions simultaneously under the same conditions.

External Remote Control

By connecting the R T-63 Remote Controller, it is possible to
simultaneously control functions such as preset value (output
value) switching and output ON/OFF status of up to 10 power
supplies.  It is also possible to per form remote control using
contact or logic signals via the RT-63.

GP-IB Control Enabling Expansion of Applications in System
Power Supplies

When used in combination with the GP-IB adapter (GP-620), the
PAR Series power supplies are applicable to automated measuring
systems and the listener/talker functions enable the control of all
functions and the reading of all output voltage and current values.
Ever y GP-620 can control up to ten  power supplied by
recognizing their IDs so a system with excellent safety can be
implemented. The system can be expanded more by increasing
the GP-620 GP-IB adapters.

Computer Control for Extension to Programmable Power
Supplies

An external computer can be directly connected to use the PAR
Series power supplies as programmable supplies and implement a
power supply system which can control all function settings and
read output voltage and current values of the supplies.

87

PAR SERIES

REGULATED DC POWER SUPPLIES

PA
R
SERIES

REGULA

TED

DC

POWER

SUPPLIES

CPU

GP  IB

GP-620

PAR Series (up to 10 units)

Listener/talker

GP-620

PAR Series (up to 10 units)

Listener/talker

PAR

PAR Series (up to 10 units)

PAR Series (up to 10 units)

Remote Controller 

RT-63

or external signals

RS-232C

CPU

PAR Series (up to 10 units)

Listener/talker

FEATURES

REMOTE CONTROL CAPABILITIES

Remote Sensing

The remote sensing terminal allows for compensation to handle
the voltage drop caused by the impedance of leads for up to 1 V
per path.

Three Preset Voltages

Up to 3 most frequently used voltage and current settings can be
preset to allow speedy output switching with a press of a button.

Output Protection

The output is interrupted when a preset key or variable key is
pressed so output of unexpected voltage or cur rent can be
prevented. (It is also possible to disable the output protection
function.)

Key Lock

A key-lock function can be used to hold all setting values and
invalidate the input of other keys than the power switch, thereby
preventing the inadvertent changes of values during experiments.

Simultaneous Display of Voltage and Current

Output voltage and current are indicated simultaneously on  7-
segment LED display to allow easy checking of the output values
and setting values.

Energy Saving Design

The energy-saving design minimize temperature rise inside the
unit, making a ventilation fan unnecessar y, and thereby
eliminating trouble such as noise, vibration and absorption of dirt.

Simplified Operation

The ease of operation is improved by adopting the one-touch
button or rotary encoder control operations for the setting of keys
and switches.

EXT CONTROL Signal Output

An open-collector signal is output for use in driving an external
relay, etc.

Содержание PAR18-5

Страница 1: ... system it will be compatible with a variety of remote control capabilities including the GP IB and computer control Additionally the built in listener talker functions make these powerful multi function power supplies possible to implement systems expansion safely for automated measuring systems and simulation testing systems PAR SERIES 18V 5A PAR18 5 36V 3A PAR36 3 GP IB OPTION Regulated DC Powe...

Страница 2: ...OWER SUPPLIES CPU GP IB GP 620 PAR Series up to 10 units Listener talker GP 620 PAR Series up to 10 units Listener talker PAR PAR Series up to 10 units PAR Series up to 10 units Remote Controller RT 63 or external signals RS 232C CPU PAR Series up to 10 units Listener talker FEATURES REMOTE CONTROL CAPABILITIES Remote Sensing The remote sensing terminal allows for compensation to handle the voltag...

Страница 3: ... less Ammeter Display 3 digits LED Maximum 9 99A display fixed range red LEDs Accuracy OUT ON 1 0 rdg 2digit at 23 5 80 RH or less Functions OUTPUT ON OFF Output on off switch but output cannot be switched on when MEMORY is on red LED lights when on OUTPUT PROTECT ON OFF Cut off the output if voltage or current setting changed red LED lights when on PRESET 1 2 3 3 sets of voltage and current value...

Страница 4: ...nly mode Can be set with the L ONLY switch Transmission delimiter selection Can be set with the EOI CR LF switch Remote local function Can be set with the Local switch Talker function Detection of the status of all outputs and settings of the controlled power supplies Listener function Detection of the status of all outputs of the controlled power supplies Service request function Notification of ...

Отзывы: