(No.RA017<Rev.003>)1-87
13.
Maxi-
mum
Devia-
tion
*2
[Analog
Wide
5k]
1) Adj item: [ADEV]
Adjust:[****]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Maxmum Devia-
tion (Analog Wide
5k)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
Write fixed value for
each adjustment point.
(The value is written be-
low.) Transmit at each
adjustment point and
check that the deviation
is between 4150Hz and
4250Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
503
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
4150~4250Hz
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
[Analog
Wide
4k]
1) Adj item:
[As ADEV]
Adjust:[****]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Maxmum Devia-
tion (Analog Wide
4k)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
Write fixed value “503”
for each adjustment
point. (The value is writ-
ten below.) Transmit at
each adjustment point
and check that the devi-
ation is between 3310Hz
and 3410Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
3310~3410Hz
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
Item
Condition
Measurement
Adjustment
Specifica-
tions
/Remarks
Panel tuning
mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method
Содержание NX-5800
Страница 118: ...MEMO ...
Страница 149: ...MEMO ...
Страница 150: ... No RA017 Rev 003 VSE Printed in Japan JVC KENWOOD Corporation Communications Systems Business Unit ...