(No.RA015<Rev.001>)1-37
*2: Wide4K can be set up only when the PC test mode is used.
*3: When P25 Phase1 is selected, in C4FM and LSM, there is an adjustment item, respectively.
16
LTR Deviation
LTR
-
9
9 *2
9
-
-
-
-
Transmitter
Section 13
1~1024
17
DTMF Deviation
DTMF
-
9
9 *2
9
-
-
-
-
Transmitter
Section 14
1~1024
18
Single Tone
Deviation
TONE
-
9
9 *2
9
-
-
-
-
Transmitter
Section 15
1~1024
19
MSK Deviation
MSK
-
9
9 *2
9
-
-
-
-
Transmitter
Section 16
1~1024
20
CW ID Deviation
CWID
-
-
-
9
-
-
-
-
Transmitter
Section 17
1~1024
21
Battery Warning
Level
BATT
(BATT
measurement value)
1point ADJ
Transmitter
Section 18
1~256
22
Sensitivity 1
SENS1
(RSSI measurement
value)
-
-
5
-
-
-
-
Receiver
Section 2
1~256
23
Sensitivity 2
SENS2
(RSSI measurement
value)
-
-
5
-
-
-
-
Receiver
Section 4
1~256
24
Sensitivity 3
SENS3
(RSSI measurement
value)
-
-
5
-
-
-
-
Receiver
Section 3
1~256
25
RSSI Reference
RRSSI
(RSSI measurement
value)
-
-
5
-
-
-
-
Receiver
Section 5
1~256
26
Open Squelch
SQL
(ASQDET
measurement value)
5
5 *2
5
5 *3
5
5
5
Receiver
Section 6
1~256
27
Low RSSI
LRSSI
(RSSI measurement
value)
-
-
5
-
-
-
-
Receiver
Section 7
1~256
28
High RSSI
HRSSI
(RSSI measurement
value)
-
-
5
-
-
-
-
Receiver
Section 8
1~256
29
Tight Squelch
SQLT
(ASQDET
measurement value)
5
5 *2
5
-
-
-
-
Receiver
Section 9
1~256
Order Adjusutment
item
Main
LCD
display
Sub LCD
display
Aw
(Analog
Wide)
As *2
(Analog
Wide 4k)
An
(Analog
Narrow)
P1
(P25
Phase1)
P2
(P25
Phase2)
Nn
(NXDN
Nar-
row)
Nv
(NXDN
Very
Nar-
row)
Adjust
item
Number
Adjustment range