K
M
O
Q
S
L
N
P
R
T
2
1
3
7
4
6
RXD-302/302E/352/352E/372S
Y39-3522-71
1
2
3
4
5
6
7
8
9
10
11
12
FMIF
AMMIX
REG
AMIF
GND
TULED
STIND
FMDET
VCC
IFBUF
AM/FM
ST/MO
24
23
22
21
20
19
18
17
16
15
14
13
OSC/FMSD
OSC
AFC
AMRF
SMET
AMOUT
FMOUT
PLLIN
MPXIN
PILOT
ROUT
LOUT
22
21
20
19
18
17
16
15
14
13
12
XOUT
VSS
AOUT
AIN
PD
VDD
FMIN
AMIN
NC
SWB+
IFIN
1
2
3
4
5
6
7
8
9
10
11
XIN
NC
CE
DI
CLK
DO
DEMF
FMB+
FM/AM
FMST
SD/IN
1
C101
0.01
C158
G
0.022
C105
0.022
C107
10.7MS
6.8K
R104
1.5K
R105
CF102
330
R106
C108
R107
100
270
R
111
10.7MG46-A
3.3K
R1
12
1u50
C1
16
+
0.47u50
C1
17
+
20P
C1
18
0.047
C109
10u50
C1
10
+
C
111
0.022
C1
14
47P
2
4
5
6
3
1
T102
1
2
3
4
6
C119
+
1u50
8.2K
R110
R123
3.3K
3.3u50
C140
+
0.022
C159
100u16
C1
13
+
0.022
C1
12
R109
10K
R108
R136 3.3K
C139 100P
+
C138 22u16
6.8K
R151
47K
R122
C132 4700P
R120 100K
0.1
C133
820P
C136
10
9
8
7
6
5
4
3
2
1
MUTE
Lch
GND
Rch
ST IND
+12V
CE
DI
CLK
DO
3
1
4
6
TC101
10P
4.7u50
+
4.7u50
C125
+
C123
C122
0.022
0.022
C124
5.6K
R1
16
3.9K
R1
17
C129 1500P
R118
3.9K
0.047
C137
0.1
T103
3
4
6
1
T104
470P
C162
30P
C164 10P
47K
R139
0.1
C161
C163 20P
10P
C165
20P
TC104
3
4
T106
1
6
1K
R138
0.022
C169
220P
220P
220P
3
4
5
1K
1K
1K
C156
R132
C154
R134
C155
R133
10K
R113
1000P
C153
1K
R119
1000P
C121
3
4
5
10P
C160
0.022
C152
10K
R150
3.3K
R124
100
R125
L106
47uH
C141 0.022
0.01
C151
47u16
C150
+
10K
R129
R126
1K
C144
100u16
+
0.022
C143
10K
R127
C145
27P
0.22
C149
5.6K
R128
0.01
C148
220
R130
20K
SFR101
CF103
1K
R103
+B
+B
2
1
TP1
+B
7.2MHz
27P
C146
X101
+B
+B
+B
+B
L
WB+
1/4W
5.6K
R1
15
1500P
C128
C131
C130
18K
R121
10u25
C134
+
2
1
IF
GND
TP2
100
R114
1000P
C120
1/4W
CF104
CANCEL
+B
+B
+B
+B
+B
+B
+B
+B
+B
+B
+B
+B
+B
+B
22uH
L107
J104
22K
R143
R131
10K
47K
R140
10K
R141
10K
R145
100K
R144
180P
C166
R146 100K
GND
IN
OUT
1/2W
C142 100u16
+
5.6K
R149
C106
100u16
+
L103
22uH
L102
22uH
R137
1K
4
8
5
3
7
6
2
J101
1000P
C102
C103
0.1
10K
R135
C167 0.022
R147 22K
R148
10K
0.022
C168
+B
+B
+B
L101
22uH
R101
22
CF101
C135
DESTINATION
DESTINATION
COUNTRY
EUROPE
EUROPE
COUNTRY
B-86
CAPE No.
ABB.
E4
CAPE No.
B-85
E3
ABB.
DESTINATION
GENERAL MARKET
COUNTRY
EUROPE
EUROPE
U.K.
CAPE No.
S-86
ABB.
E2
S-85
S-87
S-84
M
E
T
DESTINATION
COUNTRY
CAPE No.
ABB.
C101
YES
NO
131
YES
YES
NO
NO
C130,
YES
BP101
NO
YES
C101
BP101
YES
C101
YES
C130,
NO
131
YES
BP101
YES
BP101
+B
0.01
R102
0.022
22
(BOTTOM VIEW)
FE101
D101
D102
JK101
ANY
JACK 4P
Q101
AM IFT
AM/FM/MPX
SYSTEM IC
Q102
CN101
Q103
Q104
AM ANT COIL
MW OSC COIL
LW OSC COIL
Q106
Q109
Q107
D104
D103
IF AMP
D105
: SVC348S-TL
D103
: MTZJ5.6B
D101,102,104,
Q110
: 2SA733
Q103,104
: 2SK2541
Q105
: 2SK544F
Q107
: 2SC945
Q102
: 2SJ460
Q101
: 2SC1675L
Q108,109
: 2SC2001L
IC103
: LC72131
IC102
: LA1833
Q108
D105
D108
D107
BP101
Q105
Q110
D106
106-108
: 1SS133
Q106
: 2SC001L
-CN101
MAIN
4/5
RXD-302E (994B-86)
RXD-302 (994B-85)
RXD-352E (994S-86)
RXD-352 (994X-XX)
SIGNAL LINE
B LINE
1.0V
0.3V
MW999KHz:4.4V
FM98MHz:3.4V
0V
5.0V
(5.1V)
5.1V
2.4V
MW999KHz:4.3V
FM98M:3.3V
0.9V
0.9V
4.7V
(0V)
2.5V
(2.7V)
0V
2.4V
0V
2.3V
0V
0V
0V
MW/SW:0V
FM:2.8V
MW/SW:6.0V
FM:0V
MONO:0V
ST:3.2V
10.9V
OFF:0V
ON:4.6V
MUTE
ST:3.2V
2.8V(0V)
1.8V
1.8V
2.1V
0V(2.1V)
2.1V(2.3V)
2.1V
2.1V
2.7V(3.5V)
4.3V(5.0V)
2.6V(3.6V)
ST IND.ON:0V
0V
0V
2.1V
2.1V
4.3V(5.1V)
4.3V(5.1V)
2.1V
5.0V
IC102
IC103
TUNER UNIT : RXD-302(E3)/302E(E4)/352(T,E,M,X,Y)/352E(E2)
B
USED (T)TYPE
RXD-372S (2/5)
RXD-302/302E (2/5)
RXD-352/352E (2/5)
2.9V
(0.9V)
PX
AUSTRALIA
S-80
S-89
Y
X
R150
NO
R102
68
1/2W
Q103,
NO
104
W02-2681-08
FE101
E20-0321-05
JK101
C130,
NO
131
R150
NO
R102
68
1/2W
Q103,
NO
104
W02-2681-08
FE101
E20-0321-05
JK101
R150
R102
68
1/2W
680
1/4W
Q103,
NO
104
W02-2681-08
FE101
E20-0321-05
W02-2714-08
E20-0070-08
JK101
C101
YES
C130,
NO
131
R150
NO
R102
68
1/2W
Q103,
NO
104
W02-2681-08
FE101
E20-0321-05
JK101
YES
YES
NO
NO
YES
YES
NO
CAUTION: For continued safe-
ty, replace safety critical com-
ponents only with manufactur-
er's recommended parts (refer
to parts list). indicates safety
critical components. For contin-
ued protection against risk of
fire, replace only with same
type and rating fuse(s). To
reduce the risk of electric
shock, leakage-current or resis-
tance measurements shall be
carried out (exposed parts are
acceptably insulated from the
supply circuit) before the appli-
ance is returned to the cus-
tomer.
MODE
CARRIER
MODULATION
ANT
INPUT
FREQUENCY
DEVIATION
FM
98MHz
1kHz
STEREO 67.5kHz 7.5kHz(Pilot)
60dB
AM
1000(999)kHz
400Hz
MONO 30% MOD
60dB
The DC voltage is an actual reading measured with a high impedance type volt-
meter as the AM/FM signal generator is specified to the conditions as shown in the
list below. The measurement value may vary depending on the measuring instru-
ments used or on the product. The value shown in ( ) is actual reading measured
in the AM mode.
RXD-302(K)
PCBSD2,2(
99.6.18
0:11
PM
y [ W 6
w w w . x i a o y u 1 6 3 . c o m
Q Q 3 7 6 3 1 5 1 5 0
9
9
2
8
9
4
2
9
8
T E L
1 3 9 4 2 2 9 6 5 1 3
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299