KVT-M700
13
Item
Adjustment Method, Adjustment Value
Condition
3. Mechanism
First, reset by pressing both VOLDW and SRC keys at the same time and boot up the · Test Mode
Adjustment
system in Test Mode.
Display Setup screen with the FUN key, and press ADJ key for making adjustment.
Note 1: If adjustment becomes impossible as a result of having input incorrect values,
clear the E2PROM first and then conduct the adjustment. This can be done by resetting
while pressing VOLDW and OPEN/CLOSE keys. When this is done, the machine also
loses the mechanical positions. Therefore, this must also be adjusted again.
4. Confirming on the
In MONO Scope screen, confirm that the right and left positions are uniform. If they are
· MONO Scope
starting points of
off a little, use VR200 (HYOUJI) to adjust the right and left to be uniform. (Adjust to less
screen display
than one dot difference.) If the difference is much too large, adjust from the beginning of
X35 again.
5. Flicker Adjustment
Adjust with the VR302 (COM DC) so that the flicker level (60Hz content: NTSC) will be
· Input Signal
the minimum.
Composite Input Gray
RASTA (Easy to read
level of white 30~50%)
· ZOOM or CINEMA Mode
· Set it to AC range
· Flicker jig
7 5
5 7
1. X25 Circuit Adjustment Specification (K : For North American Markets)
Item
Adjustment method / Adjustment value
Conditions
1. Video detection coil
adjustment
L303
1. Turn VR301 [RF-AGC] fully to the right.
2. Apply DC2.0V to TP [IF AGC] (IC300 pin36).
3. Feed fo=45.75MHz, Mod=1kHz, AM60%, Level=100dB
µ
into TP [IF]
(A100 pin8).
4. Observe the TP [VIDEO] (IC300 pin8) waveform on an oscilloscope and
adjust L303 for maximum level.
Maximum
・
No ANT signal
・
If the waveform is clipped,
slightly increase the DC
voltage.
・
AC range
2. Audio detection coil
adjustment
L300
1. Turn VR301 [RF-AGC] fully to the right.
2. Feed fo=41.25MHz, No Modulation, Level=94dB
µ
into TP [IF] (A100 pin8).
3. Connect a voltmeter to TP [SIF] (both ends of R314) and adjust L300 for
0V
±
0.01V.
・
No ANT signal
3. S-METER adjustment
VR300
4. RF AGC adjustment
VR301
1. Turn VR301 [RF-AGC] fully to the right.
2. Feed a 30dB
µ
11CH color bar RF signal into the ANT input terminal.
3. Audio (P/S ratio -6dB) no modulation.
4. Connect a voltmeter to CN300 and adjust VR300 [SMET] so it reads
3.5V
±
0.05V.
5. Set the RF signal to 70dB
µ
and adjust VR301 [RF-AGC] so that the
voltmeter connected to CN300 reads 4.5V
±
0.05V.
・
Postpone adjusting VR301
to prevent AGC having effect
at 30dB
µ
.
・
Ensure the RF AGC
adjustment is performed
after the S-METER
adjustment.
5. Diversity free run
frequency adjustment
VR400
1. Connect a frequency counter to CN400.
2. Using the remote control unit TV/NAVI button, switch to adjustment mode.
3. Adjust VR400 [15kHz] so as to obtain 15734
±
10Hz.
・
No ANT signal
・
Test mode
ADJUSTMENT