![Kenwood KRC-225 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/kenwood/krc-225/krc-225_service-manual_1955491006.webp)
KRC-225/235/265/265S
6
MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
I/O
Description
Processing Operation
61
ACC DET
I
ACC detection input
Hi : ACC ON
62
B.U. DET
I
Momentary power down detection input
Hi : When momentary power down detected or
B.U. OFF, Lo : B.U. ON
63
S METER
I
S-meter input from the F/E
64
PANEL
I
Panel detaching detection input
Lo : Panel not detached
65
GND
I
-
Connected to GND lines.
66
GND
I
-
Connected to GND lines.
67
HOLD
I
MI-COM. HOLD input
Lo : Hold
68
VDD
-
VDD connection terminal
Connected to B.U. 5V lines.
69
GND
I
-
Connected to GND lines.
70
GND
I
-
Connected to GND lines.
71,72
-
O
-
N.C.(Not used)
73
VDD
-
Positive power supply connection terminal Connected to B.U. 5V lines.
74
GND
I
-
Connected to GND lines.
75
GND
I
-
Connected to GND lines.
76
VSS
-
Ground connection terminal
Connected to GND lines.
77,78
-
O
-
N.C.(Not used)
79
GND
-
TEST terminal 1
Connected to GND lines.
80
XOUT
O
Main clock resonator connection terminal
¶
Terminal Description ( IC1 : X14-6850-XX)