![Kenwood KR-1070VR Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/kenwood/kr-1070vr/kr-1070vr_service-manual_191923013.webp)
1060VR/1070VR/KR-V8090/KR-V9090
13
CIRCUIT DESCRIPTION
6. PLL IC expansion port control
PLL IC expansion port control list (Control data by software)
Phase locked loop integrated circuit expansion port control list (Logic that is outputted from a port [H / L H1-z]
Only L / HI-z is able to output the port of frequency modulation / amplitude
✽
1 :
modulation / LW / MONO due to Nch open drain.
✽
2 :
HI-z is made constantly because there is not LW in the specification is this time.
Operating state
Extension port
name
10
7
8
9
11
13
FM
AM
LW
MONO
RDS ATT
IF ON
IF ON
RDS ATT
ON
MONO ON
FM ON
1
0
0
1
1
0
AM ON
0
1
0
1
1
0
MONO OFF
FM ON
1
0
0
0
1
0
AM ON
0
1
0
0
1
0
RDS ATT
OFF
MONO ON
FM ON
1
0
0
1
0
0
AM ON
0
1
0
1
0
0
MONO OFF
FM ON
1
0
0
0
0
0
AM ON
0
1
0
0
0
0
IF OFF
RDS ATT
ON
MONO ON
FM ON
1
0
0
1
1
1
AM ON
0
1
0
1
1
1
MONO OFF
FM ON
1
0
0
0
1
1
AM ON
0
1
0
0
1
1
RDS ATT
OFF
MONO ON
FM ON
1
0
0
1
0
1
AM ON
0
1
0
1
0
1
MONO OFF
FM ON
1
0
0
0
0
1
AM ON
0
1
0
0
0
1
Operating state
Extension port
name
10
7
8
9
11
13
FM
AM
LW
MONO
RDS ATT
IF ON
IF ON
RDS ATT
ON
MONO ON
FM ON
L
HI-z
HI-z
L
H
L
AM ON
HI-z
L
HI-z
L
H
L
MONO OFF
FM ON
L
HI-z
HI-z
HI-z
H
L
AM ON
HI-z
L
HI-z
HI-z
H
L
RDS ATT
OFF
MONO ON
FM ON
L
HI-z
HI-z
L
L
L
AM ON
HI-z
L
HI-z
L
L
L
MONO OFF
FM ON
L
HI-z
HI-z
HI-z
L
L
AM ON
HI-z
L
HI-z
HI-z
L
L
IF OFF
RDS ATT
ON
MONO ON
FM ON
L
HI-z
HI-z
L
H
H
AM ON
HI-z
L
HI-z
L
H
H
MONO OFF
FM ON
L
HI-z
HI-z
HI-z
H
H
AM ON
HI-z
L
HI-z
HI-z
H
H
RDS ATT
OFF
MONO ON
FM ON
L
HI-z
HI-z
L
L
H
AM ON
HI-z
L
HI-z
L
L
H
MONO OFF
FM ON
L
HI-z
HI-z
HI-z
L
H
AM ON
HI-z
L
HI-z
HI-z
L
H