7
installation
8. With the door closed, check that the door
is aligned horizontally and vertically and
that the seals are closed on all sides
before finally tightening the bottom hinge.
Re-adjust the levelling feet as needed.
height regulation
845 = 100 - 170
25 - 80
845 - 890
min 590
640
890 = 180 - 250
• Do not lay the unit flat as this may damage the coolant system.
• During door reversal, when swapping the position of the bottom hinge or adjusting the
levelling feet, tilt the unit. Do not lay the unit flat.
In some cases, the door seal may be crushed after prolonged storing pressure, resulting
to the door seal not able to close properly when reversed.
Follow the steps below to solve the issue:
• Peel off the door seal from the upper or lower corner and
warm it with a hairdryer; the warmth can allow the door
seal to return to its original form. Do not blow directly on
the unit as the warmth may damage other parts of the
unit.
• Rotate the door seal upside down so that the side
originally with the hinge stay with the hinge.
• Insert the door seal back into the door from the upper or
lower corner.
• If the issue still occurs, contact your local service centre for assistance.