KDC-X959/Z939,Z738,Z838W
7
Pin No.
Pin Name
I/O
Description
Processing Operation
7
IC2 SDA
I/O Data input/output with IC2, IC5, and IC25
8
IC2 SCL
I/O Clock input/output with IC2, IC5, and IC25
9
EVDD
-
Positive power supply connection terminal
Connected to BU 5V lines.
10
EVSS
-
Ground connection terminal
Connected to GND lines.
11
PAN RESET
O
Reset output to the panel MI-COM.
Lo: Reset or Momentary power down detected
12
BEEP
O
BEEP output
13
REMO
I
Data input from the wired remote control
14
SVR
O
SVR output
Not used(N.C.)
15
DIMMER
I
Small lights detection input
Lo: During vehicle small lamps turn on
16
PLL DATA
I/O Data input/output with F/E
17
PLL CLK
I/O Clock input/output with F/E
18
P-STBY
O
POWER IC STBY output
Lo: Power IC OFF, Hi: Power IC ON or ALL OFF mode
19
P-CON
I/O P-CON output
Hi-Z: POWER OFF mode or ALL OFF mode, Hi:
POWER ON mode
20
ANT-CON
O
ANT-CON output
Hi: During TUNER mode or last FM mode with
RDS/RBDS model
21
TEST
-
Test terminal
Not used(Connected to GND lines)
22
P MUTE
O
POWER IC mute output
Lo: Muting during POWER OFF mode, ALL OFF
mode and TEL MUTE ON
23
PAN5V
I/O Panel 5V control output
Lo: Panel attached normally, Hi-Z: Panel detached
or tilted
Bass boost OFF__Hi: 160msec, Lo: 40msec
24
EXT-AMP-CON
O
External amp. control output (in 200msec)
Bass boost LOW__Hi: 130msec, Lo: 70msec
Bass boost HI__ Hi: 100msec, Lo: 100msec
25
CD MECHA+B I/O CD4.7V ON/OFF output
Lo: During CD source selected, Hi-Z: Except CD
source selected
26
EMUTE
O
Not used(N.C.)
27
BU DET
I
Momentary power down detection input
Lo: BU ON, Hi: When momentary power down
detected or BU OFF
28
ACC DET
I
ACC detection terminal
Lo: ACC ON, Hi: ACC OFF
29
SW5V
I/O SW5V control terminal
Lo: SW5V ON, Hi-Z: SW5V OFF
30
MUTE
I/O MUTE output
Lo: Muting OFF, Hi-Z: Muting ON
31
O CE
I/O External display CE terminal
32
O CLK
I/O External display clock terminal
33
O DATA
I/O External display data terminal
34
RESET
I
Reset input
Lo: System reset, Hi: Normal operation
Sub clock resonator connection terminal
Clock count during POWER OFF mode
Sub clock resonator connection terminal
Capacitor connection terminal for regulator inside
microprocessor
Main clock resonator connection terminal
Oscillation: POWER ON mode, Oscillation stop: POWER
OFF mode or momentary power down detected
Main clock resonator connection terminal
Connected to GND lines.
Positive power supply connection terminal
Connected to BU 5V lines.
Not used(N.C.)
Not used(N.C.)
44
E2PDET
I
EEPROM detection input
Lo: No EEPROM, Hi: With EEPROM
45
PRE MUTE L
O
Pre-out muting L Ch. control output
Lo: When M MUTE L input is Lo during CD source
selected or Momentary power down detected, Hi:
Fix in the case of 2 zone mode
46
PRE MUTE R
O
Pre-out muting R Ch. control output
Lo: When M MUTE R input is Lo during CD source
selected or Momentary power down detected, Hi:
Fix in the case of 2 zone mode
47
DSP DATA
O
Data output to DSP IC
Not used(N.C.)
48
DSP LATCH
O
Latch output to DSP IC
Not used(N.C.)
49
DSP CLK
O
Clock output to DSP IC
Not used(N.C.)
MICROCOMPUTER'S TERMINAL DESCRIPTION
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299