![Kenwood KDC-D301 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/kenwood/kdc-d301/kdc-d301_service-manual_189145003.webp)
KDC-D301
3
COMPONENT DESCRIPTION
●
SWITCH UNIT(X16-110X-XX)
Ref.No.
Component Name
Application/Function
Operation/Condition/Compatibility
IC1
LC75823W
LCD driver
Q1
2SC4081
Dimmer SW
When Q1's base goes "Hi", Dimmer LEDs are turned
on.
●
ELECTRIC UNIT(X25-8902-71)
Ref.No.
Component Name
Application/Function
Operation/Condition/Compatibility
IC1
UPD780058GC255
System MI-COM.
IC2
S-80830ANNP
Reset IC
When BU 5V voltage is less than 3.0V, IC outputs
"Lo".
IC5
NJM4565M-TE2
Isolation amp.
IC6
NJM4565M-TE2
1/2 VCC & A.G.C.amp.
IC7
BA3834F
BPF IC
Q1
2SC4081
BU 5V AVR
While BACKUP is applied, AVR o5V.
Q2
2SA1870 or 2SB1450
Q1 and Q2 are inverted Darlington connection.
Q3
2SC4081
Audio +B AVR
While Q3's base goes "Hi", AVR o8.0V.
Q4
2SB1202
Q5
2SC4081
IllumiB AVR
While Q5's base goes "Hi", AVR o10.5V.
Q6
2SB1202
Q7
2SC4081
Servo +B AVR
While Q7's base goes "Hi", AVR o8.0V.
Q8
2SB1202
Q9
2SC4081
BU detection SW
While BACKUP is applied, a base goes "Hi", and Q12
is turned on.
When momentary power down has detected, a base
goes "Lo", and Q12 is turned off.
Q10
2SA1037K
Panel 5V SW
When a base goes "Lo" during panel closed, Q10 is
turned on.
Q11
2SC4081
Guide or Eject illumination SW
When a base goes "Hi", Guide or Eject illumination
LED is lighting-up.
Q12
DTA143EUA
Changer mute SW
When CHANGER MUTE REQUEST to H/U is worked,
a base goes "Lo" and Q12 is turned on.
Q13
DTC144EUA or UN5213
Buzzer SW
When a base goes "Hi", Buzzer is turned on.
Q14
DTC343TK
Audio mute SW(L Ch)
When a base goes "Hi", Audio mute is activated.
Q15
DTC343TK
Audio mute SW(R Ch)
When a base goes "Hi", Audio mute is activated.
Q16
DTC144EUA or UN5213
Changer reset SW
When CHANGER RESET from H/U is worked, a base
goes "Hi" and Q19 is turned on.
Q17
UMC2N
SW 14V
Audio +8V AVR, IllumiB AVR, Servo +B AVR
on/off control
When a base goes "Hi", Q17 is turned on, and Each
AVR are working.
Q18
DTC144EUA or UN5213
BU detection inverter
Q19
UMC2N
SW 5V
CD MECHA. SW, BPF IC on/off control
When a base goes "Lo", Q19 is turned on, and Each
circuits are working.
Q20
UMC2N
Audio mute driver
When a base goes "Hi", Audio mute driver outputs
"Hi".
Q21
2SD2114K
AGC
Signal level control
Q22
DTC144EUA or UN5213
Changer control SW
When CHANGER CONTROL from H/U goes "Hi",
Q15 is turned on.
Q23
2SA1037K
LED +B SW
When Q23's base goes "Hi", BU 5V is supplied to the
Q24
DTC144EUA or UN5213
Switch Unit.