13
KDC-138/138CR/139/139S
■
LCD (ED1) short check
Procedure
Note
In the STANDBY source, press [ATT] key
All lights are off
→
Turns on odd and even terminals alternatively every
125ms (terminals that have a maximum number of grids)
→
Turns on only
the odd terminals
→
Turn on only the even terminals
→
■
Clearing CD mechanism information / Service information / DC offset error information (Clearing E2PROM data)
Status
Display
Description
While pressing and holding [2] key and
[5] key, reset-start.
C
D
O
At normal termination
C
D
–
At abnormal termination
This mode is cancelled by resetting. (The last screen will not be retained.)
Data to be cleared is shown below.
CD mechanism information
I2C communication status display
CD mechanism error log display
Displays CD loading error data
Displays CD EJECT error data
Displays CD time code count error data (missing count)
Displays CD time code count error data (count not updated)
Service Information
Power ON time display
CD operation time display
CD EJECT times display
PANEL open/close times display
Forced Power OFF information display
DC offset error information
DC offset error 1 display (Provides information on whether there is an improper connection or another error)
DC offset error 2 display (Provides information on the number of capacitor leaks)
■
Clearing DC offset error detection data (E2PROM data clearing)
Procedure
Note
While pressing and holding [3] key and [6] key, reset-start.
Entering DC offset error display mode.
Procedure
Display
Description
Press and hold the [3] and
[6] keys, and reset-start
d
C
E
R
When DC offset error is detected (when either one of capacitors is
leaking, or an improper connection or another error is detected)
d
C
O
K
When DC offset error is not detected (when none of capacitors leak,
no improper connection or other error is detected)
1
d
C
1
E
R
When improper connection or other DC offset errors are detected.
d
C
1
O
K
When improper connection or other DC offset errors are not detected.
■
1
d
C
1
O
K
When detecting improper connection or other DC offset errors, clears
detection data. (Clear E2PROM)
2
d
C
2
4
When detecting capacitor leak, provides information on the number
of capacitor leaks. (0~4)
■
2
d
C
2
0
When detecting capacitor leak, clears the number of capacitor leaks.
(Clear E2PROM)
This mode is cancelled by resetting. (The last screen will not be retained.)
TEST MODE