KDC-135/135CR/136
8
■
Example
Key
Description of display
Description
5
Disc EJECT times display
E
J
C
X
X
X
X
X
Disc EJECT times display. MAX 65535 (times)
■
5
While disc EJECT times is displayed, press and hold for
2 seconds or longer to clear disc EJECT times.
A symbol “
■
” in the key column indicates that the key should be pressed and held for 1 second or longer.
■
How to enter the test mode
Procedure
Note
Press and hold the [1] key and [3] key and reset.
All lamps blink when it is detected that the sub-clock resonator is disconnected.
When having started up in the test mode, change the LINE MUTE inhibition time from 10 seconds to 1 second.
When operating in the test mode, even if a DC offset error occurs, detection information is not written in the E2PROM.
Forced disc ejection is prohibited in the test mode.
■
How to clear the test mode
Procedure
Note
Reset, momentary power down, ACC OFF, Power OFF, Panel detached.
Clearing the test mode
■
Test mode default condition
Description
Default values
Source
STANDBY
Display
Display lights are all turned on.
Volume
-10dB (“30” is displayed.)
Bass Boost
OFF
CRSC
OFF regardless of having/not having the switching function.
AUX
ON (Only model equipped with AUX)
System Q
NATURAL (FLAT)
Beep
Sound on with a key pressed regardless of any settings.
Preout
Sub Woofer
TEST MODE