![Kenwood KDC-1032 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/kenwood/kdc-1032/kdc-1032_service-manual_188688006.webp)
6
KDC-1032/132/132CR
KDC-133/233/234SGY
Pin No.
Pin Name
I/O
Application
Truth value table
Processing Operation Description
56
LO/EJ
I/O
CD mechanism Loading/Eject switching
H: Eject, L: Loading
57
M-STOP
O
CD mechanism Stop output
H: CD ON, L: Stop
58
M-RST
O
CD mechanism Reset output
H: Normal, L: Mechanism reset
59
M-MUTE
I
CD mechanism mute input
H: Mute OFF, L: Mute ON
60
RESET
I
System
µ
-com reset input
61
REMO
I
Remote controller input
62
R-CLK
I
RDS clock input
L-output for models without RDS
63
NC
-
Not used (output L)
64
LOS SW
I
CD mechanism Loading SW detection
H: No DISC, L: DISC IN (Loading start)
65
KEY-REQ
I
Key input detection
H: No key input
(Connection with pin 11 L-DATAL)
L: Key input (Started to read Edge Key Data)
66
8EJE SW
I
12cm DISC detection
L: 12cm DISC
67
VSS0
-
68
VDD1
-
69
X2
-
MAIN X’tal oscillation circuit
4.19MHz X’tal connection
70
X1
-
MAIN X’tal oscillation circuit
4.19MHz X’tal connection
71
IC
-
TEST
72
XT2
-
NC
Open
73
XT1
-
VDD
VDD connection
74
VDD0
-
75
AVREF0
-
AD converter reference voltage
(Connection to pin 80 AVCONT)
76
S-METER
I
S-meter input
77
NOISE
I
NOISE detection (FM)
78
PHONE
I
2way Mute
2.5V or more: NAVI mute, 1.0V or less: TEL mute
L-output to the model without Phone mute
79
NC
-
Not used (output L)
80
AVCONT
O
AD reference voltage control
H: When AD converter is used
The same timing as P. ON
MICROCOMPUTER’S TERMINAL DESCRIPTION
Truth value table
q
Destination
TYPE2 (pin29)
TYPE1 (pin30)
TYPE0 (pin31)
DESTINATION
MODEL
0
0
0
K
KDC-1032/132/132CR
0
0
1
-
-
0
1
0
E
KDC-234SGA/334SA/334SAY/334SG/334SGY
0
1
1
-
-
1
0
0
-
-
1
0
1
M
KDC-132/233
1
1
0
-
-
1
1
1
J
RDT-111