Before applying power

Units are designed for operation as follows.

Europe and U.K. ..................................................................... AC 230 V only
*Other countries ............................. AC 110-120 /220-240 V switchable

For the United Kingdom

Factory fitted moulded mains plug

1. The mains plug contains a fuse. For replacement, use only a

13-Amp ASTA-approved (BS1362) fuse.

2. The fuse cover must be refitted when replacing the fuse in

the moulded plug.

3. Do not cut off the mains plug from this equipment. If the plug

fitted is not suitable for the power points in your home or the
cable is too short to reach a power point, then obtain an
appropriate safety approved extension lead or adapter, or
consult your dealer.
If nonetheless the mains plug is cut off, remove the fuse and
dispose of the plug immediately, to avoid a possible shock
hazard by inadvertent connection to the mains supply.

IMPORTANT

The wires in the mains lead are coloured in accordance

with the following code.

Blue

: Neutral

Brown : Live

Do not connect those leads to the earth terminal of a

three-pin plug.

Safety precautions

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING

 :

TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN
OR MOISTURE.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER
(OR BACK). NO USER-SERVICEABLE PARTS INSIDE, REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.

THE LIGHTNING FLASH WITH ARROWHEAD SYMBOL, WITHIN AN EQUILATERAL TRIANGLE, IS
INTENDED TO ALERT THE USER TO THE PRESENCE OF UNINSULATED “DANGEROUS VOLTAGE”
WITHIN THE PRODUCT’S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE TO CONSTITUTE
A RISK OF ELECTRIC SHOCK TO PERSONS.

THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE IS INTENDED TO ALERT THE USER
TO THE PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING) INSTRUCTIONS
IN THE LITERATURE ACCOMPANYING THE APPLIANCE.

Unpacking

Unpack the unit carefully and make sure that all accessories are put aside so they will not be lost.
Examine the unit for any possibility of shipping damage. If your unit is damaged or fails to operate, notify your dealer immediately.  If your unit
was shipped to you directly, notify the shipping company without delay. Only the consignee (the person or company receiving the unit) can file
a claim against the carrier for shipping damage.
We recommend that you retain the original carton and packing materials for use should you transport or ship the unit in the future.

Caution : Read this page carefully to ensure safe operation.

*For other countries

This unit operates on 110-120 or 220-240 volts AC . The AC voltage
selector switch on the rear panel is set to the voltage that prevails in
the area to which the unit is shipped. Before connecting the power
cord to your AC outlet, make sure that the setting position of this
switch matches your line voltage. If not, it must be set to your voltage
in accordance with the following direction.

AC voltage selection

AC voltage selector switch

Move switch lever to match
your line voltage with a small
screwdriver or other pointed
tool.

Note:

Our warranty does not cover damage caused by excessive line voltage
due to improper setting of the AC voltage selector switch.

AC 220—

240V     

AC 110—
120V 

Содержание KAF-1010

Страница 1: ...STEREO INTEGRATED AMPLIFIER B60 3742 08 00 KO T M OC 99 12 11 10 9 8 7 6 5 4 3 2 1 98 12 11 10 9 8 7 6 5 4 3 KENWOOD CORPORATION INSTRUCTION MANUAL KAF 3010R KAF 1010 ...

Страница 2: ...OLTAGE WITHIN THE PRODUCT S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO PERSONS THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE IS INTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE SERVICING INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE APPLIANCE Unpacking Unpack the unit carefully and make sure that all accessories...

Страница 3: ... Operation of remote control unit 9 Playing music 10 Normal Playback 10 Sound adjustment functions 11 To mute sound temporarily 11 Adjusting the left right sound balance 11 Adjusting the tone 11 Emphasizing deep bass LOUDNESS 11 To listen through headphones 12 Listening to high quality sound from a music source SOURCE DIRECT 12 Recording 13 To record a music source 13 In case of difficulty 14 Spec...

Страница 4: ...cluding projec tions equal to or greater than shown below Left and right panels 10 cm Rear panel 10 cm Top panel 50 cm System control cord System control cord System control cord PLAY OUT REC IN PLAY OUT REC IN U K Other countries About the AC outlet for other components KAF 3010R only SWITCHED outlet maximum capacity 200 W You can connect a power cord from a cassette deck record player or CD play...

Страница 5: ...except XR equipment Lets you synchronize recording with the start of playback when recording from CD MD or LD Notes Notes The system control connections only for KAF 3010R 1 SL16 equipment cannot be combined with XR XS and XS8 equipment for system operations If your equipment consists of this kind of combination please do not connect any system control cords Even without system control cords norma...

Страница 6: ...ating 3 Insert 2 Loosen 4 Secure Speaker system B Never short circuit the and speaker cords If the left and right speakers are connected inversely or if the speaker cords are connected with reversed polarity the sound becomes unnatural with ambiguous acoustic image positioning Be sure to connect the speakers and speaker cords correctly 1 Connect all cords firmly If connections are loose there coul...

Страница 7: ...BASS knob To adjust low frequencies 6 TREBLE knob To adjust high frequencies 7 INPUT indicator 0 An indicator lights for the source selected with the INPUT SELECTOR knob 8 VOLUME CONTROL knob 0 Adjust the volume 9 SOURCE DIRECT indicator 0 SOURCE DIRECT key To listen to a source with high quality sound PHONES jack Used for headphone listening SPEAKERS A B switches 0 Press to select the A and or B ...

Страница 8: ... system Remote control unit KAF 3010R only DISC SKIP key Only used for the Autochanger CD player INPUT SELECTOR keys AUX key does not function with this unit POWER key Use to switch the power ON STANDBY when the POWER switch is turned ON TUNER operation keys MUTING key Mute the sound temporarily VOLUME UP DOWN fi keys Adjust the volume SOURCE DIRECT key To listen to a source with high quality soun...

Страница 9: ...case change the system installation position to prevent the malfunction Loading batteries 1 Remove the cover 2 Insert batteries 3 Close the cover Pressing the POWER key on the remote control when the standby indicator is lit turns ON the power After the power comes ON press the key you want to operate Operation procedure 6 m Operating range approx Remote sensor Insert two AA size R6 SUM 3 batterie...

Страница 10: ...nes only Sound cannot be heard from the speakers A ON B OFF Set to this position when listening to the sound with the speakers connected to the SPEAKERS A terminals A OFF B ON Set to this position when listening to the sound with the speakers connected to the SPEAKERS B terminals A ON B ON Set to this position when listening to the two pairs of speakers connected to both SPEAKERS A and SPEAKERS B ...

Страница 11: ...ress the LOUDNESS key again The LOUDNESS indicator goes out Lights Make sure the SOURCE DIRECT indicator is not lit Main unit Keys or controls to be used in this operation Remote control unit KAF 3010R only MUTING MUTE BALANCE L R BASS TREBLE LOUDNESS The figure shows an example for the KAF 3010R PHONES A SPEAKER B BASS TREBLE BALANCE INPUT SELECTOR MUTING LOUDNESS ON OFF MIN MAX VOLUME CONTROL MD...

Страница 12: ...cted by the INPUT SELECTOR To cancel SOURCE DIRECT Press the SOURCE DIRECT key again The SOURCE DIRECT indicator goes out Lights Keys or controls to be used in this operation A SPEAKER B PHONES MIN MAX VOLUME CONTROL Remote control unit KAF 3010R only Remote control unit KAF 3010R only fi VOLUME CONTROL SOURCE DIRECT SOURCE DIRECT SOURCE DIRECT Sound adjustment functions The figure shows an exampl...

Страница 13: ...or the KAF 3010R When TAPE is selected with the INPUT SELECTOR recording is possible with the MD recorder When MD is selected with the INPUT SELECTOR recording is possible with the Tape deck PHONES A SPEAKER B BASS TREBLE BALANCE INPUT SELECTOR MUTING LOUDNESS ON OFF MIN MAX VOLUME CONTROL MD TAPE TUNER PHONO CD SOURCE DIRECT thermally reactive advanced instantaneous transistor T R A I T L R REMOT...

Страница 14: ...d ON with the speaker cable short circuited the speaker protection functions If the standby indicator blinks KAF 3010R or the MUTING indicator blinks KAF 1010 and no sound occurs turn the power OFF remove the short circuit then turn the power ON again Please note that resetting the microcomputer clears the contents stored in it and returns it to the condition when it left the factory The speaker c...

Страница 15: ...7 kΩ Tone control BASS 10 dB at 100 Hz TREBLE 10 dB at 10 kHz LOUDNESS control VOLUME at 30 dB level 9 dB at 100 Hz Output level impedance TAPE REC MD REC 200 mV 2 7 kΩ General Power consumption 200 W AC outlet SWITCHED 2 total 200 W max UNSWITCHED 1 100 W max Dimensions W 440 mm H 145 mm D 400 mm Weight net 8 3 kg Rated output power DIN 1 kHz at 8 Ω 40 W 40 W at 4 Ω 60 W 60 W IEC DIN from 63 Hz t...

Страница 16: ...found on the back of the unit in the spaces designated on the warranty card and in the space provided below Refer to the model and serial numbers whenever you call upon your dealer for information or service on this product Model Serial Number ...

Отзывы: